Ramping in 1 straight run
ABCB Livable Housing Design 2022 , 1.1 (4) (c) (i)
ABCB Livable Housing Design 2022 , 1.2
ABCB Livable Housing Design 2022 , 2.3
ABCB Livable Housing Design 2022 , 1.2
ABCB Livable Housing Design 2022 , 2.4 (c)
Level Landing
Clear of Door Swing
ABCB Livable Housing Design 2022 , 1.1 (3) (a)
ABCB Livable Housing Design 2022 , 1.2
Informative
Livable Housing DesignInformative
- Class 1a & 2 requirements
- Level entry into Dwelling
- Weatherproof Threshold
- Internal Door & Corridor clearances
- Sanitary compartment clearance & Wall Reinforcement
- Step-free Shower access & Wall Reinforcement
- Class 1a additional requirements
- Level Entry from Boundary or Parking Space
- Gate & Door Clearances
Step-free Access
- ≥ 1m clear width[1]
- Pedestrian Pathway to Entry from
- Property Boundary, or
- Class 10a Garage or Carport, or
- Private on-site Parking Space
- Not required for incompatible sites or where ramping can not be achieved in a straight run
Step-free Access RULES
NCC 2022 V1
Class 1a
NCC 2022 H8D2
May 2023
ABCB Livable Housing Design 2022 , 1.1
- Step-free access required for Class 1a dwellingsABCB Livable Housing Design 2022 , 1.1
- ≤ 1:14 slope in direction of travel
- ≤ 1:40 crossfall
- ≤ 1m clear width
- Landings
- ≥ 1.2m length
- ≥ ramp width
- ≤ 1:40 gradient
- Landing intervals
- ≤ 9m with 1:14 gradient
- ≤ 15m with 1:20 gradient
- Lengths calculated between 1:14 & 1:20 gradients allowed
- Level difference measured from FFL of entry to surface beneath
- Step-free Access not required for sites where
- Insufficient space for Step-free Access
- Ground exceeds allowable slope
- Path or ramp exceeds allowed length & gradient
- Access provided from attached Garage or Parking Space
ABCB Livable Housing Design 2022 , 1.1
- ≥ 1m clear widthABCB Livable Housing Design 2022 , 1.1
- Pedestrian Pathway to Entry from
- Property Boundary, or
- Class 10a Garage or Carport, or
- Private on-site Parking Space
- Not required for incompatible sites or where ramping can not be achieved in a straight run
Entrance Option 1
- Step free dwelling entry Door
- ≥ 820mm[1] clear Opening
Weatherproofing RULES
NCC 2022 V1
Class 1a & 2
NCC 2022 H8
May 2023
ABCB Livable Housing Design 2022 , 2.4
- Shall provide one or combination of the following for external step-free entranceABCB Livable Housing Design 2022 , 2.4
- Channel drain, or
- Permeable surface with ≤ 8mm drainage gaps (subject to AS 3959 if Bushfire Prone), or
- Roof covering & area falls away from the Entry
Threshold RULES
NCC 2022 V1
Class 1a & 2
NCC 2022 H8
May 2023
ABCB Livable Housing Design 2022 , 2.2
- Be level, or ≤ 5mm sill height if lip is rounded / bevelled, orABCB Livable Housing Design 2022 , 2.2
- Ramped
- ≤ 1:8 gradient
- ≤ depth of door jamb
- ≥ clear opening of Entrance Door
- Not intrude landing area, or
- Door with sill, for weatherproofing
- ≤ 15mm lip or upstand within sill profile
- ≤ 5mm ht between top of sill & adjoining finished surface
ABCB Livable Housing Design 2022 , 2.1
Entrance Option 2
- Step free dwelling entry Door from attached Car Parking[1]
- ≥ 820mm[2] clear Opening
Threshold RULES
NCC 2022 V1
Class 1a & 2
NCC 2022 H8
May 2023
ABCB Livable Housing Design 2022 , 2.2
- Be level, or ≤ 5mm sill height if lip is rounded / bevelled, orABCB Livable Housing Design 2022 , 2.2
- Ramped
- ≤ 1:8 gradient
- ≤ depth of door jamb
- ≥ clear opening of Entrance Door
- Not intrude landing area, or
- Door with sill, for weatherproofing
- ≤ 15mm lip or upstand within sill profile
- ≤ 5mm ht between top of sill & adjoining finished surface
ABCB Livable Housing Design 2022 , 2.1
ABCB Livable Housing Design 2022 , 1.2
ABCB Livable Housing Design 2022 , 1.1 (4) (b)
Ramps & Walkways
- Ramping where required can be[1]
- ≤ 1:10 Step Ramp (1 only), or
- ≤ 1:14 Ramp @ ≤ 9m, or
- ≤ 1:20 Ramp @ ≤ 15m
- with ≥ 1.2m Landings
- ≥ 1m clear width
- Handrails not mandatory but clear width must be maintained if provided
Ramp RULES
NCC 2022 V1
Class 1a
NCC 2022 H8
May 2023
NCC 2022 Vol 1, D4D4
NCC 2022 Vol 2, H5D2
ABCB Livable Housing Design 2022 , 1.1
Step Ramp RULES
NCC 2022 V4
All Building Classes
NCC 2022 D4D4 & H5D2 [2019 D3.3, 3.9.1]
May 2023
NDIS SDA Design Standard Oct 2019 Edition 1.1, 2.5
NDIS SDA Design Standard Oct 2019 Edition 1.1, 2.5
AS 1428.1:2009, 10.6.1
NCC 2022 Vol 1, D4D4
NCC 2022 Vol 2, H5D2
Slip RATING
NCC 2022 V1
All Building Classes
NCC 2022 D1P2
May 2023
ABCB Livable Housing Design 2022 , 1.1 (4)
- Ramping where required can beABCB Livable Housing Design 2022 , 1.1 (4)
- ≤ 1:10 Step Ramp (1 only), or
- ≤ 1:14 Ramp @ ≤ 9m, or
- ≤ 1:20 Ramp @ ≤ 15m
- with ≥ 1.2m Landings
- ≥ 1m clear width
- Handrails not mandatory but clear width must be maintained if provided
ABCB Livable Housing Design 2022 , 1.1 (5) (b)
ABCB Livable Housing Design 2022 , 2.3 (b)
ABCB Livable Housing Design 2022 , 1.1 (2) (a) (iv)
ABCB Livable Housing Design 2022 , 1.1 (4) (c) (i)
ABCB Livable Housing Design 2022 , 2.1