Roofing
Assembly[1] Non-combustible materials Fully sarked, junctions sealed Vents fitted with ember guards Eaves & Fascia RULES NCC 2022 V2 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.6.6 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCNCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 Roof ComponentsAS 3959:2018, 6.6.6 Gables constructed as per wall requirements Fit openings for ventilation of eaves, with ember guards & protect with screens Seals to be of corrosion-resistant aluminium, bronze, or steel Seal joints with timber storm moulds or plastic joining strips Tiled Roof RULES NCC 2022 V2 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.6.2 AS 3959:2018, 6.6.2 Roofing RULES NCC 2022 V1 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.6.1 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCNCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 RoofingAS 3959:2018, 6.6.1 Non-combustible cover Seal Roof/Roof & Roof/Wall junctions, or Backed with a breathable sarking or mesh Fit roof ventilation openings with non-combustible ember guards, or screens Evaporative coolers AS/NZS 60335.2.98 compliant If with an internal damper preventing ember entry, does not require external screening Guttering RULES NCC 2022 V2 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.6.7 Penetration RULES NCC 2022 V3 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.6.5 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCNCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 Roof PenetrationAS 3959:2018, 6.6.5 Sealed with non-combustible material Openings screened ≥ 4mm toughened Grade A safety glass for overhead glazing Fit evaporative coolers with non-combustible butterfly closers, or Non-combustible covers with screens ≤ 2mm aperture size or opening Screen RULES NCC 2022 V3 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 3.6.1 AS 3959:2018, 6.4.3 Skylight RULES NCC 2022 V2 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.6.5 (e) AS 3959:2018, 6.6.5 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCNCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 SkylightAS 3959:2018, 6.6.5 (e) Sealed / fully flashed with non-combustible material Grade A safety glass to AS 1288Polymer skylight allowed with Grade A safety glass diffuser below glazing Insulated glazing unit requires ≥ 4mm thick Grade A toughened safety glass to outer panel Tubular SkylightsAS 3959:2018, 6.6.5 Flashing may consist of fire-retardant materials ≤ 5 Flammability Index of under-flashingMetal Sheet Roof RULES NCC 2022 V2 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.6.3 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCNCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 Sheet RoofsAS 3959:2018, 6.6.3 Fully sarked over battens Insulation blankets with foil backing can be placed above the battens Seal gaps along fascia, ridges, hips, & wall lines by any of the following Mesh or perforated screen Mineral wool Non-combustible material AS 3959:2018, 6.6.1 AssemblyAS 3959:2018, 6.6.1 Non-combustible materials Fully sarked, junctions sealed Vents fitted with ember guards Decks & Landing
Fully enclosing a sub-floor will provide protection[1] Non-combustible material[2] Deck & Landing RULES NCC 2022 V4 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.7.1 AS 3959:2018, 6.7.2.4 AS 3959:2018, 6.7.2.1 NSW RFS 2019 PBP, 7.5.2 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCNCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 Decking may be spacedAS 3959:2018, 6.7.1 & has no requirements unless < 300mm horizontally & < 400mm vertically from a glazed Window or DoorAS 3959:2018, 6.7.2.4 , then must be Non-combustible material Bushfire-resisting Timber Allowed Timber Species If Enclosing Walls are constructed & ≤ 400mm from ground AS 3959:2018, 6.7.2.1 Non-combustible material, or Bushfire-resisting Timber, or Allowed Timber Species NSW Enhanced RULES NSW RFS 2019 PBP, 7.5.2
Decks, Landings & Stairs must be constructed to BAL-29 requirements All elements must be Non-combustible material, or Bushfire-resisting Timber Bushfire-resisting Timber BAL-19 NCC 2022 V4 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, F4 AS 3959:2018, E1 AS 3959:2018, 1.5.5 AS 3959:2018, 6.7.2.4 AS 3959:2018, 6.3.2.1 Penetrations
Protection[1] Sealed with non-combustible materials Screen all openings Penetration RULES NCC 2022 V3 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.6.5 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCNCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 Roof PenetrationAS 3959:2018, 6.6.5 Sealed with non-combustible material Openings screened ≥ 4mm toughened Grade A safety glass for overhead glazing Fit evaporative coolers with non-combustible butterfly closers, or Non-combustible covers with screens ≤ 2mm aperture size or opening Screen RULES NCC 2022 V3 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 3.6.1 AS 3959:2018, 6.4.3 AS 3959:2018, 6.6.5 Doors, Frames, Sidelights
Doors with seals all round[1] Non-combustible Panels[2] Framing materials[3] Metal Bushfire-resistant timber Allowed timber species Metal-reinforced uPVC ≥ 5mm T oughened Glass[4] Door RULES NCC 2022 V2 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.5.4 (c) (v) AS 3959:2018, 6.5.4 (c) (vii) AS 3959:2018, 6.5.4 (c) (i) AS 3959:2018, 6.5.4 (c) (ii) AS 3959:2018, 6.5.4 (c) (iv) AS 3959:2018, 6.5.4 (a) AS 3959:2018, 6.5.4 (b) Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCNCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 Door Assembly Install seals & weather stripsAS 3959:2018, 6.5.4 (c) (v) Tight-fitting to door frame and abutting doorAS 3959:2018, 6.5.4 (c) (vii) Door LeafAS 3959:2018, 6.5.4 (c) (i) ≥ 35mm thk reconstituted, laminated, or solid timber for first 400mm above threshold, orHollow core, or reconstituted timber, with non-combustible kickplate for first 400mm above threshold Glazed door panels with full framing made of metal, bushfire-resisting timber, uPVC, or allowed timber species FramesAS 3959:2018, 6.5.4 (c) (ii) Metal, bushfire-resisting timber, allowed timber species, or metal-reinforced uPVC Metal reinforcement to be of aluminium, stainless steel, or corrosion-resistant steel GlazingAS 3959:2018, 6.5.4 (c) (iv) ≥ 5mm toughened glass No requirements on door if Protected by a bushfire shutter, orAS 3959:2018, 6.5.4 (a) Protected by screensAS 3959:2018, 6.5.4 (b) Bushfire-resisting Timber BAL-19 NCC 2022 V4 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, F4 AS 3959:2018, E1 AS 3959:2018, 1.5.5 Screen RULES NCC 2022 V3 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 3.6.1 AS 3959:2018, 6.4.3 AS 3959:2018, 6.5.4 (c) (v) AS 3959:2018, 6.5.4 (c) (i) (A) AS 3959:2018, 6.5.4 (c) (iv) AS 3959:2018, 6.5.4 (c) (ii) Garage & Carport Under
All elements to BAL-19 Rules [1] , orFire separated Carport or Garage Under or Partially Under a Building NCC 2022 V2 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 3.2.2 (a) AS 3959:2018, 3.2.2 (b) AS 3959:2018, 3.2.2 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCC Specification 1, NCC Part G5, & AS 3959 NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 Walls, Ceilings, Floors, Structure & Openings to BAL-19 rulesAS 3959:2018, 3.2.2 (a) , or Separate from the main building withAS 3959:2018, 3.2.2 (b) 60/60/60 Structure tested from Outside-/60/60 Walls & ceiling / floor above, or≥ 90mm thk Masonry or Earth WallsAS 3959:2018, 3.2.2 -/60/30 Self-closing fire door-/60/- Permanently closed fire windowAS 3959:2018, 3.2.2 Floor & Balcony
Fully enclosing the sub-floor will provide protection[1] Non-combustible materials if unenclosed[2] Unenclosed Sub-floor RULES NCC 2022 V3 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.2 AS 3959:2018, 6.3.2.2 (a) (i) AS 3959:2018, 6.3.2.2 (a) (ii) Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCNCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 Bearers, Joists, & Flooring < 400mm from ground to be of AS 3959:2018, 6.2 Non-combustible material, or Bushfire-resisting timber FlooringAS 3959:2018, 6.3.2.2 (a) (i) Non-combustible Bushfire resisting Timber Timber, particleboard, or plywood, with underside covered by sarking or mineral wool, or AS 1530.8.1 compliant system Sub-floor spaceAS 3959:2018, 6.3.2.2 (a) (ii) Avoid storing combustible materials underneath Keep free of leaf litter Bushfire-resisting Timber BAL-19 NCC 2022 V4 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, F4 AS 3959:2018, E1 AS 3959:2018, 1.5.5 Sub-floor Support RULES NCC 2022 V3 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.2 AS 3959:2018, 6.2 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCNCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 Unenclosed SubfloorAS 3959:2018, 6.2 Non-combustible material Bushfire-resisting timber or approved timber species Avoid storing combustible materials in the Subfloor space No requirements when Subfloor space is enclosed withAS 3959:2018, 6.2 BAL-19 compliant Wall, orProtected by screens Fully-enclosed Sub-floor RULES NCC 2022 V3 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.3.2.1 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCNCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 No requirements when subfloor is enclosed with AS 3959:2018, 6.3.2.1 BAL-19 compliant wall, or Protected by screens ≤ 2mm aperture size or openingAluminium, bronze, or corrosion-resistant steel Ember Holding Surface NCC 2022 V3 Remember Embers can blow & accumulate against a vertical building element causing it to ignite Any surface including ground, deck, or roof can hold embers if < 18° slope & if > 110mm width Screen RULES NCC 2022 V3 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 3.6.1 AS 3959:2018, 6.4.3 Wall Construction RULES NCC 2022 V3 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.4.1 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCNCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 External Wall ≤ 400mm from Ground or DecksAS 3959:2018, 6.4.1 Wall must be fully sarked ≥ 90mm thk Non-combustible materialsMasonry Wall Precast Concrete Wall Earth Wall (Mud Brick) ≥ 90mm thk Timber logs (≥ 680kg/m³ density)Cladding secured to the exterior of a timber or steel-framed wall. Non-combustible material ≥ 6mm Fibre-cementBushfire-resisting Timber Approved Timber Species Steel sheeting Any combination of the options above AS 3959:2018, 6.3.2.2 AS 3959:2018, 6.3.2.1 Wall Lining Installation (FRL)
Eaves & Fascia
Roof Components[1] Gables shall follow same rules as per Fire Wall Eaves penetrations screened Joints sealed Eaves & Fascia RULES NCC 2022 V2 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.6.6 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCNCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 Roof ComponentsAS 3959:2018, 6.6.6 Gables constructed as per wall requirements Fit openings for ventilation of eaves, with ember guards & protect with screens Seals to be of corrosion-resistant aluminium, bronze, or steel Seal joints with timber storm moulds or plastic joining strips Screen RULES NCC 2022 V3 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 3.6.1 AS 3959:2018, 6.4.3 AS 3959:2018, 6.6.6 Roof ComponentsAS 3959:2018, 6.6.6 Gables shall follow same rules as per Fire Wall Eaves penetrations screened Joints sealed Sarking
≤ 5 Flammability Index[1] Roofs need a full layer of Sarking[2] Sarking RULES NCC 2022 V3 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 3.10 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCNCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 SarkingAS 3959:2018, 3.10 ≤ 5 Flammability IndexNon-combustible material Continuous to the outside to walls & roof Type of Sarking varies on structural location, consulting a professional is recommended AS 3959:2018, 3.10 AS 3959:2018, 6.6 Walls
Non-combustible material[1] Bushfire-resisting Timber[2] Joints sealed or covered[3] Jointing RULES NCC 2022 V3 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.4.2 Bushfire-resisting Timber BAL-19 NCC 2022 V4 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, F4 AS 3959:2018, E1 AS 3959:2018, 1.5.5 Ember Holding Surface NCC 2022 V3 Remember Embers can blow & accumulate against a vertical building element causing it to ignite Any surface including ground, deck, or roof can hold embers if < 18° slope & if > 110mm width Vent & Weephole RULES NCC 2022 V2 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.4.3 Wall Construction RULES NCC 2022 V3 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.4.1 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCNCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 External Wall ≤ 400mm from Ground or DecksAS 3959:2018, 6.4.1 Wall must be fully sarked ≥ 90mm thk Non-combustible materialsMasonry Wall Precast Concrete Wall Earth Wall (Mud Brick) ≥ 90mm thk Timber logs (≥ 680kg/m³ density)Cladding secured to the exterior of a timber or steel-framed wall. Non-combustible material ≥ 6mm Fibre-cementBushfire-resisting Timber Approved Timber Species Steel sheeting Any combination of the options above AS 3959:2018, 6.4.1 (a) AS 3959:2018, 6.4.1 (c) (iii) AS 3959:2018, 6.4.2 Detached Structure
> 6m separation[1] , orSame Fire-resisting construction[2] , or Main Building protected by[3] ≥ –/60/60 FRL Non-loadbearing wall≥ 60/60/60 FRL Loadbearing wall–/60/30 FRL Self-closing fire door–/60/– FRL permanently closed WindowDetached Structure RULES NCC 2022 V3 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 3.2.3 AS 3959:2018, 3.2.3 (a) AS 3959:2018, 3.2.3 (b) AS 3959:2018, 3.2.3 (c) Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCNCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 The main building can be protected by having the detached structure with equivalent fire-resisting construction as the main building, orAS 3959:2018, 3.2.3 Separation from Main BuildingAS 3959:2018, 3.2.3 (a) ≥ 6m horizontal distance, orFire Wall protecting main buildingAS 3959:2018, 3.2.3 (b) ≥ 60/60/60 Loadbearing wall≥ -/60/60 Non-loadbearing wall-/60/30 self-closing Fire Door-/60/- permanently closed window & other openingsMasonry WallAS 3959:2018, 3.2.3 (c) ≥ 90mm thk leaf Masonry, masonry-veneer, or earth Openings protected as above Fire Doors & Windows to comply to AS 1905.1 & AS 1530.4 AS 3959:2018, 3.2.3 (a) AS 3959:2018, 3.2.3 AS 3959:2018, 3.2.3 (b) Vent & Weepholes
Use rust-proof screens for Vents[1] Non-combustible access door[2] Door RULES NCC 2022 V2 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.5.4 (c) (v) AS 3959:2018, 6.5.4 (c) (vii) AS 3959:2018, 6.5.4 (c) (i) AS 3959:2018, 6.5.4 (c) (ii) AS 3959:2018, 6.5.4 (c) (iv) AS 3959:2018, 6.5.4 (a) AS 3959:2018, 6.5.4 (b) Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCNCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 Door Assembly Install seals & weather stripsAS 3959:2018, 6.5.4 (c) (v) Tight-fitting to door frame and abutting doorAS 3959:2018, 6.5.4 (c) (vii) Door LeafAS 3959:2018, 6.5.4 (c) (i) ≥ 35mm thk reconstituted, laminated, or solid timber for first 400mm above threshold, orHollow core, or reconstituted timber, with non-combustible kickplate for first 400mm above threshold Glazed door panels with full framing made of metal, bushfire-resisting timber, uPVC, or allowed timber species FramesAS 3959:2018, 6.5.4 (c) (ii) Metal, bushfire-resisting timber, allowed timber species, or metal-reinforced uPVC Metal reinforcement to be of aluminium, stainless steel, or corrosion-resistant steel GlazingAS 3959:2018, 6.5.4 (c) (iv) ≥ 5mm toughened glass No requirements on door if Protected by a bushfire shutter, orAS 3959:2018, 6.5.4 (a) Protected by screensAS 3959:2018, 6.5.4 (b) Vent & Weephole RULES NCC 2022 V2 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.4.3 AS 3959:2018, 6.4.3 AS 3959:2018, 6.5.4 (c) (i) (A) Attached Structure
Same fire-resisting construction as Main Building[1] or Main Building is protected by[2] ≥ –/60/60 FRL Non-loadbearing wall ≥ 60/60/60 FRL Loadbearing wall–/60/30 FRL self-closing fi re door–/60/– FRL permanently closed WindowAttached Structure RULES NCC 2022 V2 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 3.2.1 AS 3959:2018, 3.2.2 AS 3959:2018, 3.2.1 (b) AS 3959:2018, 3.2.1 (a) Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCNCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 The main building can be protected by having the attached structure with equivalent fire resisting construction as the main building, orAS 3959:2018, 3.2.1 Fire Wall required if structure is a garageAS 3959:2018, 3.2.2 Openings protected byAS 3959:2018, 3.2.1 (b) ≥ 60/60/60 FRL Loadbearing wall≥ –/60/60 FRL Non-loadbearing wall–/60/30 FRL Self-closing Fire Door–/60/– FRL permanently closed windowMasonry WallAS 3959:2018, 3.2.1 (a) ≥ 90mm thk leafMasonry, masonry-veneer, or earth Openings protected as above Fire Doors & Windows to comply to AS 1905.1 & AS 1530.4 AS 3959:2018, 3.2.1 AS 3959:2018, 3.2.1 (a) Same fire-resisting construction as Main BuildingAS 3959:2018, 3.2.1 or Main Building is protected byAS 3959:2018, 3.2.1 (a) ≥ –/60/60 FRL Non-loadbearing wall ≥ 60/60/60 FRL Loadbearing wall–/60/30 FRL self-closing fi re door–/60/– FRL permanently closed WindowVerandah or Awning Roof
Relation to main roof[1] If part of main roof space, requirements as per main roof If separated, non-combustible cover Tiled Roof RULES NCC 2022 V2 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.6.2 AS 3959:2018, 6.6.2 Ancillary Roofing RULES NCC 2022 V3 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.6.4 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCNCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 Carport, Overhead Awning, & Verandah RoofsAS 3959:2018, 6.6.4 If part of main roof, shall follow main roof requirements If separated from main roof, a non-combustible cover shall be used & shall follow wall requirements Post RULES NCC 2022 V3 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.7.5 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCNCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 Verandah Posts may be ofAS 3959:2018, 6.7.5 Timber installed on galvanised mounting shoes or stirrups With a clearance ≥ 75mm above the surrounding ground level, or If < 400mm above deck or ground level, must be of either Non-combustible material, or Bushfire-resisting timber, or Allowed timber species Metal Sheet Roof RULES NCC 2022 V2 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.6.3 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCNCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 Sheet RoofsAS 3959:2018, 6.6.3 Fully sarked over battens Insulation blankets with foil backing can be placed above the battens Seal gaps along fascia, ridges, hips, & wall lines by any of the following Mesh or perforated screen Mineral wool Non-combustible material AS 3959:2018, 6.6.4 Relation to main roofAS 3959:2018, 6.6.4 If part of main roof space, requirements as per main roof If separated, non-combustible cover Bushfire Shutter
Made of materials resistant to combustion[1] Optional & removes window & door requirements[2] [3] ≤ 2mm aperture gaps, slots, or screen[4] Bushfire Shutter RULES NCC 2022 V2 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.5.3 AS 3959:2018, 3.7 AS 3959:2018, 6.5.1 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCNCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 OptionalAS 3959:2018, 6.5.3 If not installed, window & door assemblies shall comply with corresponding BAL requirements Bushfire ShutterAS 3959:2018, 3.7 AS 3959:2018, 6.5.1 ≥ 1 to be openable from inside to allow escapeMust cover the entire window or door assembly Able to be closed manually in case of power failure ≤ 2mm gap to wall, frame, & sill≤ 20% perforated area, uniformly distributed, with ≤ 2mm aperturesBushfire-resisting Timber BAL-19 NCC 2022 V4 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, F4 AS 3959:2018, E1 AS 3959:2018, 1.5.5 Screen RULES NCC 2022 V3 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 3.6.1 AS 3959:2018, 6.4.3 AS 3959:2018, 6.5.1 (a) AS 3959:2018, 3.7 AS 3959:2018, 6.5.3 AS 3959:2018, 6.5.4 Services
Metal for Plumbing above ground[1] Power lines to be buried[2] Utility Service RULES NCC 2022 V1 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 NSW RFS 2019 PBP, 5.3.3 AS 3959:2018, 6.8 AS/NZS 1596:2014, 4.4.12 NSW RFS 2019 PBP, 5.3.3 NSW RFS 2019 PBP, 5.3.3 AS 3959:2018, 6.8 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCNCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 Water Supply Metal above-ground Water Pipes, Taps, Storage TankNSW RFS 2019 PBP, 5.3.3 Fire Hydrants prohibited on road carriagewayAS 3959:2018, 6.8 Gas Services Steel or Copper above-ground Gas PipesAS/NZS 1596:2014, 4.4.12 ≥ 0.9mm w all thickness (Gas regulations may require thicker)≥ 400mm extension inside the building≥ 100mm underground extensionRefer to local Gas regulations for additional information Bottled Gas InstallationNSW RFS 2019 PBP, 5.3.3 NSW RFS 2019 PBP, 5.3.3 Shield or locate away from building Away from flammable materials Connections are made of metal Polymer-sheathed flexible gas supply lines are prohibited Electricity ServicesAS 3959:2018, 6.8 Power lines to be buried where applicable Overhead lines 30m Pole spacingRefer to ISSC3 for Managing Vegetation Near Power Lines AS 3959:2018, 6.8 NSW RFS 2019 PBP, 5.3.3 Garage Doors
Non-combustible materials[1] ≤ 5 Flammability Index to seals[2] Use screens to cover the ventilation slots[3] Bushfire-resisting Timber BAL-19 NCC 2022 V4 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, F4 AS 3959:2018, E1 AS 3959:2018, 1.5.5 Garage Doors RULES NCC 2022 V2 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.5.6 AS 3959:2018, 6.5.6 (b) AS 3959:2018, 6.5.6 (c) AS 3959:2018, 6.5.6 (d) Screen RULES NCC 2022 V3 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 3.6.1 AS 3959:2018, 6.4.3 AS 3959:2018, 6.5.6 (a) (i) AS 3959:2018, 6.5.6 (c) AS 3959:2018, 6.5.6 (d) Guttering & Downpipes
Box Gutter non-combustible & fully flashed [1] Turn sarking into Gutter [2] Guttering RULES NCC 2022 V2 All Building Classes
NCC 2022 G5D1 & H7D4 [2019 G5.0, 3.10.5]
May 2023
NCC 2022 Vol 1, G5D1 NCC 2022 Vol 2, H7D4 AS 3959:2018, 6.6.7 AS 3959:2018, 6.6.7 AS 3959:2018, 6.6 Redirecting... (5)