Bushfire Prone Development Building Codes & Rules


- Ensure fire-safe construction in Bushfire-Prone Areas with Tools™. Comply with NCC Part G5 & AS 3959, incorporating best practices for resilience.


Water Supply


  • Available for use by fire fighters[1]
  • Outlet location protected and accessible
  • Hydrants in street if available
  • Tank in rural areas
  • 5 to 10kl capacity dependent on lot size
  • Steel & or buried pipework


Static Water Supply (SWS)


NCC 2022 V2


All Building Classes


NCC 2022 G5D2, H7D4, & S1

[2019 G5.1, 3.10.5, Sch 5]


May 2023



NCC 2022 Vol 1, G5D2

NCC 2022 Vol 2, H7D4

NCC 2022 Vol 3, S1

NSW 2019 Planning for Bushfire Protection, 6.8.3

NSW 2019 Planning for Bushfire Protection, 5.3.3

-/60/60 FRL

NSW 2019 Planning for Bushfire Protection, 2.2

Bushfire Prone MappingNSW 2019 Planning for Bushfire Protection, 2.2

  • Verify Bushfire Prone Area with your State Bushfire Authority

Vegetation Assessment

Property Boundary

Property Boundary

Edge of Vegetation

Downslope Assessment

AS 3959:2018, 2.2.5

AS 3959:2018, 2.2.5

NSW 2019 Planning for Bushfire Protection, 3.2

APZNSW 2019 Planning for Bushfire Protection, 3.2

AS 3959:2018, 2.2.5

100mAS 3959:2018, 2.2.5

Fire Danger Index (FDI)


  • Regional climate & weather patterns can vary fire intensity[1]


FDI DEFINITION


NCC 2022 V3


All Building Classes


NCC 2022 G5D2, H7D4, & S1

[2019 G5.1, 3.10.5, Sch 5]


May 2023



NCC 2022 Vol 1, G5D2

NCC 2022 Vol 2, H7D4

NCC 2022 Vol 3, S1

AS 3959:2018, 1.5.14

AS 3959:2018, 2.2.2

AS 3959:2018, 2.2.2

Vegetation


  • Vegetation classes have varying risks[1]
  • 100m from any vertical structure considered[2]


Vegetation Class ASSESSMENT


NCC 2022 V2


All Building Classes


NCC 2022 G5D2, H7D4, & S1

[2019 G5.1, 3.10.5, Sch 5]


May 2023



NCC 2022 Vol 1, G5D2

NCC 2022 Vol 2, H7D4

NCC 2022 Vol 3, S1

AS 3959:2018, 2.2.3

AS 3959:2018, 2.2.4

AS 3959:2018, 2.2.3.1

AS 3959:2018, 2.2.3.2

NSW 2019 Planning for Bushfire Protection, A4.1.1

NSW 2019 Planning for Bushfire Protection, 3.2

Protection Zone (APZ & IPZ)


  • Maintained area between building & Classified Vegetation[1][2]
  • Width determined by risk
  • Within subject property


Inner Protection Area (IPA)


NCC 2022 V2


All Building Classes


NCC 2022 G5D2, H7D4, & S1

[2019 G5.1, 3.10.5, Sch 5]


May 2023



NCC 2022 Vol 1, G5D2

NCC 2022 Vol 2, H7D4

NCC 2022 Vol 3, S1

NSW 2019 Planning for Bushfire Protection, A4.1.1

Asset Protection Zone


NCC 2022 V2


All Building Classes


NCC 2022 G5D2, H7D4, & S1

[2019 G5.1, 3.10.5, Sch 5]


May 2023



NCC 2022 Vol 1, G5D2

NCC 2022 Vol 2, H7D4

NCC 2022 Vol 3, S1

NSW 2019 Planning for Bushfire Protection, 3.2

NSW 2019 Planning for Bushfire Protection, A4.1

NSW 2019 Planning for Bushfire Protection, A4.1

NSW 2019 Planning for Bushfire Protection, A4.1.1

AS 3959:2018, 2.2.3.1

Downslope Angle


  • 100m average Terrain slope[1]
  • Measured from the edge of Classified Vegetation


Downslope Angle ASSESSMENT


NCC 2022 V1


All Building Classes


NCC 2022 G5D2, H7D4, & S1

[2019 G5.1, 3.10.5, Sch 5]


May 2023



NCC 2022 Vol 1, G5D2

NCC 2022 Vol 2, H7D4

NCC 2022 Vol 3, S1

AS 3959:2018, 2.2.5

AS 3959:2018, 2.2.5

Rainwater

Redirecting... (5)