Energy Efficiency Building Codes & Rules


- Discover practical ways to navigate Section J of NCC for energy efficiency, from design tips to best practices for insulation and sealing, with Building Tools.


Building Insulation

Recommends to

Insulate Metal Pipes

Industry Recommendation

Building OrientationIndustry Recommendation

  • Orient living spaces towards the north to maximize the winter sun, use shading devices for summer
  • North-facing Walls & Windows
  • Requires more sunlight in winter which helps warm building during colder months
  • East & West-facing Walls & Windows
  • Receives more sunlight during summer
  • May lead to overheating if not managed properly
  • Summer Shading
  • Adopt eaves or overhangs designed to block direct sunlight in summer

Outward

Heat Flow

NCC 2022 Vol 2, H6V2 (3) (p)

NCC 2022 Vol 2, H6V2 (3) (q)

NCC 2022 Vol 2, H6P1

NCC 2022 Vol 1, J2D2

Thermal Performance for Class 1 & 10NCC 2022 Vol 2, H6V2 (3) (p)NCC 2022 Vol 2, H6V2 (3) (q)

  • Cooling Setting
  • 24°C for Bedrooms
  • 26°C for Other Habitable Rooms
  • Heating Setting
  • 20°C All Habitable Rooms
  • Enhance comfort in living spaces
  • Optimize energy consumption based on climate conditions
  • Reduce the environmental impact of heating & cooling system
  • Thermal performance requirements as per the NCCNCC 2022 Vol 2, H6P1

Thermal Performance for Class 2 to 9NCC 2022 Vol 1, J2D2

  • Heating & cooling loads of habitable rooms & conditioned spaces to comply to the NCC
  • Minimum required load limit calculation
  • Ensures that the heating & cooling systems maintains efficient & comfortable indoor temperature

NCC 2022 Vol 1, J1F1

NCC 2022 Vol 2, H6F1

Energy EfficiencyNCC 2022 Vol 1, J1F1NCC 2022 Vol 2, H6F1

  • Considers future installations & improvements for energy consumption
  • A building should aim to
  • Lower energy consumption for sustainability
  • Be environmentally friendly
  • Enhance occupant well-being

Industry Recommendation

NCC 2022 HP, 13.2.5 (3)

NCC 2022 HP, 13.2.5 (5)

NCC 2022 HP, 13.2.5 (6)

External Wall Requirements

  • Solar AbsorptanceIndustry Recommendation
  • ≤ 70% absorption for General or Lightweight Wall Construction
  • Metal-Framed Walls Thermal BridgingNCC 2022 HP, 13.2.5 (3)NCC 2022 HP, 13.2.5 (5)
  • ≥ R0.2 thermal value of thermal breaks at all contact points where the metal frame meets the external cladding
  • Except if walls are made from insulated sandwich panels

Other Wall ConsiderationsNCC 2022 HP, 13.2.5 (6)

  • Insulation
  • Use bulk or reflective insulation
  • ≥ R2.8 Thermal Insulation Value with outward heat flow
  • Values vary when factoring on-site conditions
  • Construction System
  • Consider using composite thermal mass construction

Industry Recommendation

Industry Recommendation

NCC 2022 HP, 13.2.3 (2)

Roof & Ceiling Requirements

  • Reflective InsulationIndustry Recommendation
  • ≤ 0.05 surface emittance with
  • ≥ 20mm air circulation gap adjacent to a roof
  • Reflective surface to face downward
  • Thermal Insulation ValuesIndustry Recommendation
  • Use bulk & reflective insulation for ceiling
  • ≥ R4.1 Thermal Insulation Value for < 40% solar absorptance (Very light coloured roof)
  • ≥ R4.6 Thermal Insulation Value for 40 to 60% solar absorptance (Light coloured roof)
  • ≥ R5.1 Thermal Insulation Value for < 60% solar absorptance (Dark coloured roof)
  • Values vary when considering on-site conditions
  • Choose light coloured roof materialsNCC 2022 HP, 13.2.3 (2)

Industry Recommendation

Heating & Cooling RequirementsIndustry Recommendation

  • Passive solar heating & evaporative cooling
  • Consider use of Hydronic Heating
  • Install ceiling fans within living & sleeping areas

Industry Recommendation

Industry Recommendation

NCC 2022 HP, 13.2.6 (4)

Floor Requirements

  • For In-slab or In-screed Heating & Cooling System InsulationIndustry Recommendation
  • ≥ R1.0 Thermal Insulation Value
  • Install around the vertical edge of the slab’s perimeter
  • Prevent heat loss or gain at the slab edges
  • InsulationIndustry Recommendation
  • ≥ R2.25 Thermal Insulation Value with outward heat flow
  • Values vary when considering on-site conditions
  • Construction SystemNCC 2022 HP, 13.2.6 (4)
  • Consider in-slab hydronic systems
  • Earth-coupled slabs are extremely useful to reduce heat loss

Cold Air from

Evaporative Cooler

Outward

Heat Flow

Hot Air into

Evaporative Cooler

Informative

Climate Zone 5: Warm TemperateInformative

  • Mild winter, low humidity
  • Hot to very hot summers, low to moderate humidity
  • Aim to minimize heating during winter & cooling in summer
  • Consult local Energy Assessor for commercial & complex projects
  • Check State & Territory Government on Energy Efficiency Requirements

Outward Heat Flow

NCC 2022 Vol 1, J1P4

Electrical Vehicle Charging EquipmentNCC 2022 Vol 1, J1P4

  • Provide sufficient electrical capacity & pre-wiring of EV charging stations
  • Dedicate parking spaces ready for EV use

NCC 2022 HP, 13.4.7

Evaporative Coolers with Self-closing DamperNCC 2022 HP, 13.4.7

  • In heated spaces
  • Dampers keep warm air in & prevents cold air from entering when the cooler isn’t running
  • For Habitable Rooms in Cold Climate Zones 4, 5, 6, 7 & 8
  • Helps maintain comfortable indoor temperatures & prevents drafts
  • Damper improves efficiency and comfort by controlling airflow when the cooler is not in use

Use Hydronic Heating

Hot water to heat the space

Industry Recommendation

Considering Sustainable Energy UpgradesIndustry Recommendation

  • LED Upgrade
  • 80 to 90% savings on electricity bill than fluorescent or incandescent bulbs
  • Lasts longer & are more efficient
  • Heat Pump Hot Water Upgrade
  • Consider replacing gas hot water systems with Electric Heat Pumps
  • 3x more efficient than gas
  • Reduces energy bills & health risks related to gas usage
  • Solar Upgrade
  • Harness clean, renewable energy from the sun
  • Boosts business profit by reducing electricity cost

Industry Recommendation

Renewable EnergyIndustry Recommendation

  • Electricity Generation
  • Install Solar Panels on building roof
  • This provides a clean & renewable energy source directly from the sun
  • Hot Water Systems
  • Solar Thermal System - collects sunlight to heat water (commonly used in residential applications)
  • Heat Pump System - extracts heat from the surrounding air, water, or ground to heat water
  • Solar Heating & Cooling Systems
  • Uses solar thermal system to power cooling & to provide space & water heating
  • Passive Solar Design Solutions
  • Building orientation
  • Window placement
  • Use suitable materials to regulate indoor temperature

Ceiling Fans in all Living

& Sleeping Spaces

Passive Solar Heating

to North-facing Openings

Passive Solar Heating

to North-facing Openings

Adjustable Shade Screens that exclude Low-angle Sun

Electric Vehicle Parking

Windows & Shading


  • Be able to reduce ≥ 80% of summer sun with the use of External Shading Devices[1]


Window RULES


NCC 2022 V1


  • Limit glazing
  • Carefully size & position window openings
  • Apply double glazing to all habitable rooms
  • Thermally improve frame quality
  • North-facing Windows
  • Go for a High Solar Heat Gain Coefficient (SHGC)
  • With passive shading
  • East & West Windows
  • Select low SHGC coatings to reduce heat gain
  • Protect from summer sun
  • South-facing Window
  • Use low U-value & high visible light transmittance

Shading RULE


NCC 2022 V1


All Building Classes


NCC 2022 HP, 13.3.4


May 2023



NCC 2022 HP, 13.3.4

  • Shading devices must be tailored to the local climate and latitudeNCC 2022 HP, 13.3.4
  • Measure based on the solar heat gain of windows depending on
  • Season (Winter or Summer),
  • Climate Zone
  • Building Orientation &
  • Shading performance (P/H) ratio
  • Shading performance (P/H) ratio
  • Higher P/H value decreases summer heat gain
  • Lower P/H value beneficial for winter solar access
  • Adjustable shading battens or slats can be operated by manually, mechanically or electronically
  • Can reduce summer sun by ≥ 80%

NCC 2022 HP, 13.3.4

  • Be able to reduce ≥ 80% of summer sun with the use of External Shading DevicesNCC 2022 HP, 13.3.4

Condensation

Building Sealing

Climate Zone Map