Fixtures, hardware & services
Fixture Height 900mm to 1.1m from FFL[1] General Purpose Outlets (GPO) 600mm to 1.1m from FFL[2] Fixture RULES NCC 2022 V3 Class 1 & 10a
NCC 2022 F4D5 [2019 F2.4]
May 2023
AS 1428.1:2009, 15.4.3 NCC 2022 Vol 1, F4D5 AS 1428.1:2009, 15.4.3 Switches and Outlets RULES NCC 2022 V1 Class 1 & 10a
NCC 2022 F4D5 [2019 F2.4]
May 2023
AS 1428.1:2009, 14.1 AS 1428.1:2009, 14.1 AS 1428.1:2009, 14 AS 1428.1:2009, 14.1 AS 1428.1:2009, 14.2 NCC 2022 Vol 1, F4D5 AS 1428.1:2009, 15.4.3 AS 1428.1:2009, 14.1 AS 1428.1:2009, 15.3.1 (d) AS 1428.1:2009, 15.4.1 AS 1428.1:2009, 15.4.1 AS 1288:2021, 5.8.1 AS 1428.1:2009, 15.4.1 AS 1288:2021, 5.8.1 AS 1428.1:2009, 15.4.3 AS 1428.1:2009, 15.4.3 AS 1428.1:2009, 15.3.2 (b) AS 1428.1:2009, 15.3.2 (b) AS 1428.1:2009, 15.3.2 (c) AS 1428.1:2009, 15.3.2 (d) (i) (B) AS 1428.1:2009, 15.4.1 AS 1428.1:2009, 15.3.2 (a) AS 1428.1:2009, 15.3.2 (c) AS 1428.1:2009, 15.3.2 (b) AS 1428.1:2009, 15.3.2 (a) AS 1428.1:2009, 15.3.2 (c) Vanity
Optional & provides Shelf space of ≥ 120mm width x ≥ 300mm depth[1] [2] Shelf RULES NCC 2022 V3 Class 2 to 9
NCC 2022 F4D5 [2019 F2.4]
May 2023
AS 1428.1:2009, 15.3.2 (d) (i) (A) AS 1428.1:2009, 15.3.2 (d) (i) (B) AS 1428.1:2009, 15.3.2 (d) (i) (C) AS 1428.1:2009, 15.3.2 (d) (ii) (A) AS 1428.1:2009, 15.3.2 (d) (ii) (A) AS 1428.1:2009, 15.3.2 (d) (ii) (A) AS 1428.1:2009, 15.3.2 (d) (ii) (B) AS 1428.1:2009, 15.3.2 (d) (ii) (B) NCC 2022 Vol 1, F4D5 AS 1428.1:2009, 15.3.2 Provision of access for people with disabilities in compliance to NCC Part F4 & AS 1428.1AS 1428.1:2009, 15.3.2 (d) (i) (A) AS 1428.1:2009, 15.3.2 (d) (i) (B) Shelf space should be provided next to the washbasin in one of these ways Shelf as a Part of Vanity Bench 800 to 830mm height from FFLAS 1428.1:2009, 15.3.2 (d) (i) (C) ≥ 120mm width x ≥ 300mm depthAS 1428.1:2009, 15.3.2 (d) (ii) (A) AS 1428.1:2009, 15.3.2 (d) (ii) (A) Shelf as Separate Fixture w ithin circulation space900mm to 1m height from FFLAS 1428.1:2009, 15.3.2 (d) (ii) (A) ≥ 850mm undersurface clearanceAS 1428.1:2009, 15.3.2 (d) (ii) (B) 120 to 150mm width x 300 to 400mm depthAS 1428.1:2009, 15.3.2 (d) (ii) (B) Shelf as Separate Fixture o utside circulation space800mm to 1m heightNCC 2022 Vol 1, F4D5 ≥ 120mm width x ≥ 400mm depthAS 1428.1:2009, 15.3.2 AS 1428.1:2009, 15.3.2 (d) (i) (B) AS 1428.1:2009, 15.3.2 (d) (i) (C) Door
Swing or Sliding Door allowed Emergency openable from outside[1] ≥ 530mm circulation space next to Door[2] Swing Door RULES NCC 2022 V3 All Building Classes
NCC 2022 F4D5 [2019 F2.4]
May 2023
AS 1428.1:2009, 15.2.9 (a) AS 1428.1:2009, 15.2.9 (b) AS 1428.1:2009, 15.2.9 (a) AS 1428.1:2009, 13.5.2 (e) Provision of access for people with disabilities in compliance to NCC Part F4 & AS 1428.1 Latchless hold-close system mandatory for outward DoorsAS 1428.1:2009, 15.2.9 (a) Visible occupancy indicator & secure locking (bolt or catch) required, with emergency outside accessAS 1428.1:2009, 15.2.9 (b) Snib Handle ≥ 45mm distance from centre of SpindleAS 1428.1:2009, 15.2.9 (a) ≤ 20N opening, swinging & holding force with stable position between 60 to 90° AS 1428.1:2009, 13.5.2 (e) AS 1428.1 compliant Lever Handle requiredInward opening Door Clearance options as per detail below AS 1428.1:2009, 15.2.9 (b) AS 1428.1:2009, 15.6 (b) (iii) Water Provision
Lever Handles, Sensor Plate or similar Taps[1] Plumbing outside Clearance Zone[2] Water Provision RULES NCC 2022 V3 Class 1 & 10a
NCC 2022 F4D5 [2019 F2.4]
May 2023
AS 1428.1:2009, 15.2.1 AS 1428.1:2009, 15.2.1 NCC 2022 Vol 1, F4D5 Provision of access for people with disabilities in compliance to NCC Part F4 & AS 1428.1AS 1428.1:2009, 15.2.1 AS 1428.1:2009, 15.2.1 Water Taps NCC 2022 Vol 1, F4D5 Lever handles, Sensor Plate & the like ≥ 50mm from adjacent interior finishHorizontal Configuration Hot Water Tap located on the left to the Cold Water Tap Vertical Configuration Hot Water Tap located above the Cold Water Tap Mixing Spout for hot water provision AS 1428.1:2009, 15.2.1 (a) AS 1428.1:2009, 15.3.2 (b) Redirecting... (5)