Shower (Accessible) Building Codes & Rules


- Ensure compliance with NCC for accessible showers. Tools™ simplifies rules, preventing errors, optimising efficiency.


AS 1428.1:2009, 15.5.9

470

to

480AS 1428.1:2009, 15.5.9

AS 1428.1:2009, 15.4.4

1.2m

to

1.35mAS 1428.1:2009, 15.4.4

AS 1428.1:2009, 15.5.9

≤ 100AS 1428.1:2009, 15.5.9

AS 1428.1:2009, 15.5.2 (b)

580 ± 25AS 1428.1:2009, 15.5.2 (b)

AS 1428.1:2009, 15.5.2 (c)

1:60 to 1:80AS 1428.1:2009, 15.5.2 (c)

End of Seat

End of Seat

Fall

Fall

AS 1428.1:2009, 15.5.10

Clothes HooksAS 1428.1:2009, 15.5.10

  • 2 required within 600mm of the seat

Folding Seat

Tap & Soap Zone

Ø 50 Shower & Grabrail Clearance

AS 1428.1:2009, 15.5.6 (a)

580 to 600AS 1428.1:2009, 15.5.6 (a)

AS 1428.1:2009, 15.5.7

AS 1428.1:2009, 15.5.8

200AS 1428.1:2009, 15.5.7AS 1428.1:2009, 15.5.8

AS 1428.1:2009, 15.5.2 (b)

550 ± 25AS 1428.1:2009, 15.5.2 (b)

AS 1428.1:2009, 15.5.6 (c)

1 to

1.1mAS 1428.1:2009, 15.5.6 (c)

AS 1428.1:2009, 15.5.4

800 ± 10AS 1428.1:2009, 15.5.4

AS 1428.1:2009, 15.5.4

700 ± 5AS 1428.1:2009, 15.5.4

AS 1428.1:2009, 15.5.10

400 ± 10AS 1428.1:2009, 15.5.10

AS 1428.1:2009, 15.5.4

390

to

400AS 1428.1:2009, 15.5.4

AS 1428.1:2009, 15.5.10

600 ± 10AS 1428.1:2009, 15.5.10

AS 1428.1:2009, 15.5.2 (d)

1:80 to 1:100AS 1428.1:2009, 15.5.2 (d)

AS 1428.1:2009, 15.6

1.1mAS 1428.1:2009, 15.6

Folding Seat


  • ≥ 1m clear to wall or other obstruction opposite when folded[1]


Folding Seat SPECIFICATION


NCC 2022 V2


Class 2 to 9


NCC 2022 F4D5 [2019 F2.4]


May 2023



NCC 2022 Vol 1, F4D5

AS 1428.1:2009, 15.5.9

AS 1428.1:2009, 15.5.9 (a)

AS 1428.1:2009, 15.5.9

AS 1428.1:2009, 15.5.9 (c)

AS 1428.1:2009, 15.5.9 (d)

AS 1428.1:2009, 15.5.9 (e)

AS 1428.1:2009, 15.5.9

AS 1428.1:2009, 15.5.9

AS 1428.1:2009, 15.5.4

50

to

60AS 1428.1:2009, 15.5.4

AS 1428.1:2009, 15.5.7

AS 1428.1:2009, 15.5.8

800AS 1428.1:2009, 15.5.7AS 1428.1:2009, 15.5.8

Grabrails


  • Ø 30 to 40mm[1][2]
  • ≥ 660mm long for horizontal grabrail[3]
  • Optionally integrated with Shower Head Rail


Grabrail RULES


NCC 2022 V6


All Building Classes


NCC 2022 F4D5 [2019 F2.4]


May 2023



AS 1428.1:2009, 17 (c)

AS 1428.1:2009, 17 (a)

AS 1428.1:2009, 17 (b)

AS 1428.1:2009, 17 (d)

AS 1428.1:2009, 17 (e)

NCC 2022 Vol 1, F4D5

AS 1428.1:2009, 15.5.4

AS 1428.1:2009, 17 (a)

AS 1428.1:2009, 17 (d)

AS 1428.1:2009, 15.5.7

AS 1428.1:2009, 15.5.8

300AS 1428.1:2009, 15.5.7AS 1428.1:2009, 15.5.8

Shower


  • Hand-held with ≥ 1.5m flexible hose[1]
  • 1 to 1.8m height adjustable[2]
  • 700mm ± 5 for wall outlet above FFL[3]


Shower RULES


NCC 2022 V2


Class 2 to 9


NCC 2022 F4D5 [2019 F2.4]


May 2023



AS 1428.1:2009, 15.5.6

AS 1428.1:2009, 15.5.6 (b)

AS 1428.1:2009, 15.5.6 (c)

AS 1428.1:2009, 15.5.6 (a)

NCC 2022 Vol 1, F4D5

AS 1428.1:2009, 15.5.6

AS 1428.1:2009, 15.5.6 (c)

AS 1428.1:2009, 15.5.6 (a)

AS 1428.1:2009, 15.5.1

AS 1428.1:2009, 15.5.6 (a)

AS 1428.1:2009, 15.6

AS 1428.1:2009, 15.5.9

AS 1428.1:2009, 15.5.9

Circulation Space


  • Shower recess in corner of a room (2 walls)[1]
  • 1.6m x 2.35m including shower
  • Shower recess within 3 walls or other fixture[2]
  • 1.6m x 1.4m space outside of shower


Circulation EXAMPLES


NCC 2022 V2


All Building Classes


NCC 2022 F4D5 [2019 F2.4]


May 2023



AS 1428.1:2009, 15.6

AS 1428.1:2009, 15.5.1 (a)

NCC 2022 Vol 1, F4D5

  • Provision of access for people with disabilities in compliance to NCC Part F4 & AS 1428.1AS 1428.1:2009, 15.6
  • Only the following shower fittings are allowed within this space ≥ 900mm from finished floorAS 1428.1:2009, 15.5.1 (a)NCC 2022 Vol 1, F4D5
  • Grabrails
  • Shower / hose fittings & taps
  • Soap holder & shelf (if provided)
  • Folding seat

AS 1428.1:2009, 15.6

AS 1428.1:2009, 15.6