Infill Glazed (Balustrade) Building Codes & Rules


- Wire balustrades may look sleek, but they’re risky. Learn why they fail compliance and how Tools™ helps you design safer balustrades with confidence.


Span

AS 1288:2021, 7.4.7.2

Two Edge "U" Channel SupportAS 1288:2021, 7.4.7.2

  • Safety Glass Types Allowed
  • Laminated Annealed
  • Laminated Heat Toughened
  • Toughened (monolithic) if ≤ 5m Fall Risk
  • Laminated Toughened
  • Fully supported Edges
  • Similar rule applies to top & bottom support

Live Load

Fixings


  • Seal to prevent water ingress


Fixings


NCC 2022 V2


  • Seal to prevent water ingress

AS 1288:2021, 7.4.7.3

Two Edge Support Mechanical FixedAS 1288:2021, 7.4.7.3

  • Safety Glass Types Allowed
  • Laminated Heat Strengthened
  • Toughened (monolithic) if ≤ 5m Fall Risk
  • Laminated Toughened

NCC 2022 Vol 1, D3D20 (1)

Non-climbable Zone (NCZ)

NCZ

NCZ

Span

Glazing Span


  • Two Edge Support by
  • Continuous "U" channel, or
  • Mechanical Fixings
  • Balustrade system & Glazing Engineered to relevant Codes


Glass Span RULES


NCC 2022 V3


All Building Classes


NCC 2022 B1D4, H1D8, H6D2 [B1.4, 3.6, 3.12.3]


May 2023



AS 1288:2021, 7.4.7.2

AS 1288:2021, 7.4.7.3

  • Glazed Assemblies to comply to NCC Part B1D4, H1D8, H6D2, & AS 1288

Glass

  • Two Edge Support by
  • Continuous "U" channel, or
  • Mechanical Fixings
  • Balustrade system & Glazing Engineered to relevant Codes

Grade A

Safety Glass

Grade A

Safety Glass

≥ 1.05m

NCC 2022 Vol 1, D3D20 (1)

760NCC 2022 Vol 1, D3D20 (1)

Wind Load

Three-edge Support (optional)

NCZ

NCC 2022 Vol 1, NSW D3D18 (1) (d) (ii)

≥ 1.2mNCC 2022 Vol 1, NSW D3D18 (1) (d) (ii)

9b

Entertainment

Venue (NSW)

NCC 2022 Vol 1, D3D18 (1) (d)

≥ 1mNCC 2022 Vol 1, D3D18 (1) (d)

NCC 2022 Vol 1, D3D20 (1)

150NCC 2022 Vol 1, D3D20 (1)

AS 1288:2021, 7.4.7.3

FAS 1288:2021, 7.4.7.3

AS 1288:2021, 7.4.7.3

≤ F / 4AS 1288:2021, 7.4.7.3

AS 1288:2021, 7.4.7.3

≤ F / 4AS 1288:2021, 7.4.7.3

Balustrade


  • Load Support
  • Fall risk ≥ 1m[1][2]
  • Handrail mechanically fixed to structure
  • Glazed infill panels
  • Ø 125mm sphere unable to pass between any part of the barrier[3][4]


Balustrade RULES


NCC 2022 V1


All Building Classes


NCC 2022 B1D4, H1D8, H6D2 [B1.4, 3.6, 3.12.3]


May 2023



Balustrade BEST PRACTICE


NCC 2022 V2


  • Any balustrade system to withstand expected loads
  • Must be designed and structurally certified
  • Dependent on the location and use
  • Glazed systems rely on a common rail or specialized laminated glass to prevent fall if a panel fails
  • Confirm acceptance of system & selection with owner & certifier
  • Where a balustrade meets a window or other uneven element, mullion or transom, openings may become larger than allowed
  • Ø 125mm opening compliance may be affected
  • Risk for climbing
  • Fixed furniture, taps etc. must not be installed near a balustrade
  • Wire balustrades
  • Avoid as this requires regular maintenance
  • Have high certification failure rate & facilitate climbing

NCC 2022 Vol 1, D3D19 (1)

NCC 2022 HP, 11.3.4 (4)

NCC 2022 Vol 1, D3D17 (1)

NCC 2022 HP, 11.3.3 (1)