Awning windows
Impact RISK
NCC 2022 V1
NCC 2022 HP, 8.4.3
NCC 2022 HP, 8.4.3
AS 1428.1:2021, 3.6
AS 1428.1:2021, 3.6
NCC 2022 HP, 8.4.7 (2)
AS 1428.1:2021, 3.6
AS 1288:2021, 5.1
AS 1288:2021, 5.1
NCC 2022 HP, 8.4.2
NCC 2022 HP, 8.4.2
AS 1288:2021, 5.1
Glazing Audit
Side light below 1.2m
Glass NEAR DOORS
NCC 2022 V1
All Building Classes
NCC 2022 8.4.3 [2019 3.6.4.2]
May 2023
NCC 2022 HP, 8.4.2
NCC 2022 HP, 8.4.3 (1)
NCC 2022 HP, 8.4.3 (1) (a)
NCC 2022 HP, 8.4.3 (1) (b)
NCC 2022 HP, 8.4.2
Windows above 500
- Low impact risk[1]
- Annealed glazing
Glazing at Low IMPACT RISK
NCC 2022 V1
Class 1 & 10
NCC 2022 8.3.3 [2019 3.6.3]
May 2023
NCC 2022 HP, 8.3.3 (a)
NCC 2022 HP, 8.3.3 (b)
NCC 2022 HP, 8.3.3 (c)
NCC 2022 HP, 8.4.4 (2) (b)
NCC 2022 HP, 8.3.3
Side light above 1.2m
- Monolithic Annealed Glass[1]
Glass NEAR DOORS
NCC 2022 V1
All Building Classes
NCC 2022 8.4.3 [2019 3.6.4.2]
May 2023
NCC 2022 HP, 8.4.2
NCC 2022 HP, 8.4.3 (1)
NCC 2022 HP, 8.4.3 (1) (a)
NCC 2022 HP, 8.4.3 (1) (b)
NCC 2022 HP, 8.4.2
NCC 2022 HP, 8.4.7 (2)
Full Height Window
- Grade A Safety Glass[1]
- Must be made readily visible
Fully Framed GLAZING
NCC 2022 V1
All Building Classes
NCC 2022 8.4.2, 8.4.4 [2019 3.6.4.1, 3.6.4.3]
May 2023
NCC 2022 HP, 8.4.4 (1)
NCC 2022 HP, 8.4.7
NCC 2022 HP, 8.4.2
NCC 2022 HP, 8.4.4 (1)
NCC 2022 HP, 8.4.7 (2)
Louvred Windows
- Grade A Toughened Safety Glass[1][2]
- Any height near a door
- Thickness depends on blade size
Glass Louvres NEAR DOORS
NCC 2022 V1
All Building Classes
NCC 2022 8.4.3 [2019 3.6.4.2]
May 2023
NCC 2022 HP, 8.4.3 (1) (c)
- Grade A Toughened Safety GlassNCC 2022 HP, 8.4.3 (1) (c)
- ≥ 5mm thick if
- < 230mm wide and
- < 1m long
- ≥ 10mm thick if
- > 230mm wide
- All exposed glass edges must not be sharp
AS 1288:2021, 5.12
NCC 2022 HP, 8.4.3 (1) (c)
Doors
- Fully framed glazing[1]
- Grade A Safety Glass
- Frameless glazing[2]
- ≥ 10mm thk Toughened Safety Glass or
- Laminated safety lass
Fully Framed GLAZING
NCC 2022 V1
All Building Classes
NCC 2022 8.4.2, 8.4.4 [2019 3.6.4.1, 3.6.4.3]
May 2023
NCC 2022 HP, 8.4.4 (1)
NCC 2022 HP, 8.4.7
NCC 2022 HP, 8.4.2
NCC 2022 HP, 8.4.2 (a)
NCC 2022 HP, 8.4.4 (1)
Fall Prevention
- Bedroom or Child Care Facility
- > 2m[1] internal floor level to ground below
- > 1.7m[2] sill height or must be secure
- All other windows
- > 4m[3] internal floor level to ground below
- > 865mm[4] sill height or must be secure
Fall Prevention RULES
NCC 2022 V3
All Building Classes
NCC 2022 D3D29 [2019 D2.24]
May 2023
NCC 2022 Vol 1, D3D29 (2)
NCC 2022 Vol 1, D3D29 (3)
NCC 2022 Vol 1, D3D29 (2) (b) (i)
NCC 2022 Vol 1, D3D29 (3) (b)
NCC 2022 Vol 1, D3D29 (1)
NCC 2022 Vol 1, D3D29 (3)
NCC 2022 Vol 1, D3D29 (2)
NCC 2022 Vol 1, D3D29 (3) (b)
NCC 2022 Vol 1, D3D29 (1)
Making glass visible
- If glass can be mistaken for an opening[1]
- ≥ 20mm[2] thk opaque band or motif (Class 1 & 10)
- Where part of an Accessible Path of Travel[3]
- ≥ 75mm thk solid non-transparent band of ≥ 30% luminance contrasting colour
Is Glass VISIBLE?
NCC 2022 V1
All Building Classes
NCC 2022 8.4.4 [2019 3.6.4.3]
May 2023
NCC 2022 HP, 8.4.4 (2) (c)
- Marking is not required if glazing isNCC 2022 HP, 8.4.4 (2) (c)
- Opaque, or
- Patterned, or
- Colonial bars, or
- Features that indicate its presence
NCC 2022 HP, 8.4.7 (2)
AS 1428.1:2021, 3.6
NCC 2022 HP, 8.4.7 (1)