Roof Glazing Building Codes & Rules


- Roof Glazing Tools™ simplifies the National Construction Code (NCC) with interactive graphics, including deemed to comply & best practices.


Roof Windows & Skylights

Ventilation


  • Non-vented
  • Passive
  • Openable
  • Electric (Skylight & Dome Fans)
  • Solar


Rooflight Ventilation TYPES


NCC 2022 V1


null
  • Non-vented
  • Passive
  • Openable
  • Electric (Skylight & Dome Fans)
  • Solar

Maintenance


  • Check base components every[1]
  • 12 months clean debris, wash coating
  • 6 months if leaf risk
  • Access for maintenance to have Safety Label & not located in trafficable areas


Rooflight MAINTENANCE


NCC 2022 V2


All Building Classes


NCC 2022 S5C16, J4D5, J5D4, HP13.2.4, & HP13.4.3

[2019 Spec C1.1:3.6, J1.4, J3.3, 3.12.1.3, 3.12.3.2]


May 2023



  • Rooflights to be energy-efficient, fire-resistant, sealed or capable of being sealed, and constructed to the NCC
  • Do not use window cleaning fluid on polymers
  • Use scratch-proof cleaning materials
  • Clean glass / polymers with mild or natural detergent
  • Use warm water & rinse well
  • Base Components
  • Inspect periodically
  • Remove leaf & rubbish build-up
  • Glazing, Timber, & Mechanical Accessories
  • Check every 12 months
  • Lubricate mechanical parts

AS 4285:2019, F

  • Check base components everyAS 4285:2019, F
  • 12 months clean debris, wash coating
  • 6 months if leaf risk
  • Access for maintenance to have Safety Label & not located in trafficable areas

Fire Resisting Construction


  • Type A Construction[1]
  • Non-combustible materials


Roof Light FRL


NCC 2022 V2


Class 2 to 9


NCC 2022 S5C16 [2019 Spec C1.1: 3.6]


May 2023



NCC 2022 Vol 1, S5C16 (a)

NCC 2022 Vol 1, S5C16 (b)

NCC 2022 Vol 1, S5C16 (b) (i)

NCC 2022 Vol 1, S5C16 (b) (iii)

NCC 2022 Vol 1, S5C16 (b) (iv)

NCC 2022 Vol 1, S5C16 (b) (ii)

NCC 2022 Vol 1, S5C16 (c)

Where Roof FRL is required, Roof Light to be

NCC 2022 Vol 1, S5C11 (1)

Shafts & Lightwell


  • Flat, smooth, clean, & reflective surface[1]
  • Surface must hinder the collection of dust
  • Maximise light throughput


Rooflight Shaft TYPES


NCC 2022 V1


  • Splayed or Flared
  • Shaftless
  • Straight
  • Flexible
  • Tubular
  • Specular or semi-specular lightwells
  • ≥ 85% Specular Reflectance
  • > 2m long, highly specular

AS 4285:2019, C

  • Flat, smooth, clean, & reflective surfaceAS 4285:2019, C
  • Surface must hinder the collection of dust
  • Maximise light throughput

Typical Sizes


  • Derived from[1]
  • Lightwell specular reflectivity, Tubular Skylights
  • Diffuse, other Skylights
  • Consider[2]
  • Site's geographic location
  • Rooflight location on the roof
  • Shape of shaft and its reflectivity


Rooflight SIZES


NCC 2022 V1


null

AS 4285:2019, D

AS 4285:2019, D

  • Derived fromAS 4285:2019, D
  • Lightwell specular reflectivity, Tubular Skylights
  • Diffuse, other Skylights
  • ConsiderAS 4285:2019, D
  • Site's geographic location
  • Rooflight location on the roof
  • Shape of shaft and its reflectivity

Energy Efficiency


  • Required to be weatherproof & sealed[1]
  • Installed with ceiling diffusers[2]
  • Has a shutter system[3]


Roof Light Building Sealing Energy Efficiency


NCC 2022 V1


Class 1 & 10a


NCC 2022 HP13.2.4 & 13.4.3 [2019: 3.12.1.3 & 3.12.3.2]


May 2023



NCC 2022 HP, 13.2.4 (a)

NCC 2022 HP, 13.2.4 (b) (ii)

NCC 2022 HP, 13.2.4 (b) (i)

Thermal Performance (for NSW)


NCC 2022 V1


All Building Classes


NCC 2022 S5C16, J4D5, J5D4, HP13.2.4, & HP13.4.3

[2019 Spec C1.1:3.6, J1.4, J3.3, 3.12.1.3, 3.12.3.2]


May 2023



  • Rooflights to be energy-efficient, fire-resistant, sealed or capable of being sealed, and constructed to the NCC
  • DIY Method
  • ≤ 300m² conditioned floor area
  • Glazing to be 10 to 40% of conditioned floor area
  • ≤ 3m² cumulative area of Rooflights & Roof Windows
  • 1 to 2 storeys high for single dwellings
  • ≤ 25m² Open Mezzanine

NCC 2022 HP, 13.4.3 (1)

NCC 2022 HP, 13.4.3 (2) (a)

NCC 2022 HP, 13.4.3 (2) (c)

AS/NZS 2589:2017, B3

AS/NZS 2589:2017, B4

Glancing LightAS/NZS 2589:2017, B3AS/NZS 2589:2017, B4

  • Emphasises surface variations
  • Level 5 Plasterboard Finish to minimise Glancing Light issues

Fall

Bushfire Construction


  • Seal openings including gaps & vents[1]


Roof Penetration Bushfire CONSTRUCTION


NCC 2022 V1


All Building Classes


NCC 2022 G5 & H7D4 [2019 Part G5 & 3.10.5]


May 2023



  • Buildings located in Bushfire Prone Areas to address bushfire attack risks and be constructed to the NCC

NCC 2022 Vol 1, G5O1 (b)

Glass Roofing

Types of Rooflight


  • Deck Mounted
  • Curb Mounted


Rooflight TYPES


NCC 2022 V1


null
  • Deck Mounted
  • Curb Mounted
Redirecting... (5)
Please wait while we redirect you to the correct page.