Windows & Skylight (Roofing) Building Codes & Rules


- Roof Windows & Skylights: Tools™ simplifies the National Construction Code (NCC) with interactive graphics, including deemed to comply & best practices.


Purlin

Roof Sheeting

Manufacturer's Recommendation - -, -

Flashing KitManufacturer's Recommendation - -, -

  • Install into opening using appropriate fastener & sealant on all overlaps
  • Ends to form lapped mitre corners

Turn down &

notch to roof profile

Curb Support

AS 4285:2019, 1.7

AS 4285:2019, 2.1.1

WeathertightnessAS 4285:2019, 1.7AS 4285:2019, 2.1.1

  • Apply sealant around the perimeter of the framing for a watertight seal around the curb
  • Use compatible & durable sealants, gaskets, & weatherstrips against harsh climate conditions
  • Seal & fasten end of Ribs above Soaker Gutter
  • Provide anti-capillary cuts on female ribs for overlapping sheets

HB 39:2015, 5.5 (b)

Soaker Gutter

Plasterboard Lining

Insulation

Purlin

Sarking

Weather

Trough Ends

Manufacturer's Recommendation - -, -

LocationManufacturer's Recommendation - -, -

  • Positioned to match the room's lighting needs
  • Clear of obstructions, such as
  • Overhanging trees
  • Roof parts
  • Utility systems
  • Vents & other piping

Insulation

Weather Fold & Seal

Insulation

AS 4285:2019, C

Shaft Surface

Closed Ribs &

Anti-capillary Cut

Curb Support

≥ 200

HB 39:2015, 2.9 (b)

≤ 40HB 39:2015, 2.9 (b)

HB 39:2015, 5.5 (g)

≥ 100HB 39:2015, 5.5 (g)

HB 39:2015, 5.5 (g)

≥ 100HB 39:2015, 5.5 (g)

Overhead Glazing


  • Grade A Safety Glass[1]


Sloped Overhead Glazing RULES


NCC 2022 V1


All Building Classes


NCC 2022 F6D3, B1F2, S5C16, J4D5, J5D4, HP13.2.4, & HP13.4.3

[2019 F4.2, BF1.2 Spec C1.1:3.6, J1.4, J3.3, 3.12.1.3, 3.12.3.2]


May 2023



AS 1288:2021, 6.3 (b)

AS 1288:2021, 6.3 (a)

AS 1288:2021, 6.3 (a)

  • Rooflights to be energy-efficient, fire-resistant, sealed or capable of being sealed, and constructed to the NCC
  • Grade A Laminated Safety Glass
  • Grade A Toughened Safety Glass
  • ≤ 500mmAS 1288:2021, 6.3 (b) wide, if Glazing 3mAS 1288:2021, 6.3 (a) above finished floor
  • For outer pane of IGU, if ≥ 3mAS 1288:2021, 6.3 (a) above finished floor
  • Inner pane to be Laminated Glass

AS 1288:2021, 6.3

Shaft & Lightwell


  • Flat, smooth, clean, & reflective surface[1]
  • Surface should hinder collection of dust
  • Maximise light throughput


Rooflight Shaft TYPES


NCC 2022 V1


  • Splayed or Flared
  • Shaftless
  • Straight
  • Flexible
  • Tubular
  • Specular or semi-specular lightwells
  • ≥ 85% Specular Reflectance
  • > 2m long, highly specular

AS 4285:2019, C

  • Flat, smooth, clean, & reflective surfaceAS 4285:2019, C
  • Surface should hinder collection of dust
  • Maximise light throughput

Turn up ends level with Rib

Typical Sizes


  • Derived from[1]
  • Lightwell specular reflectivity, Tubular Skylights
  • Diffuse, other Skylights
  • Consider[2]
  • Site's geographic location
  • Rooflight location on the roof
  • Shape of shaft and its reflectivity


Rooflight SIZES


NCC 2022 V1


null

AS 4285:2019, D

AS 4285:2019, D

  • Derived fromAS 4285:2019, D
  • Lightwell specular reflectivity, Tubular Skylights
  • Diffuse, other Skylights
  • ConsiderAS 4285:2019, D
  • Site's geographic location
  • Rooflight location on the roof
  • Shape of shaft and its reflectivity

Sarking

Insulation

Ceiling

Installation

  • Installed to Manufacturer's Instructions, by a qualified tradesperson
  • Tested and passed in accordance with AS 4285
  • Ability to withstand concentrated loads
  • Ability to withstand wind forces
  • Weathertightness

AS 4285:2019, 1.8

Rooflight Assembly FinishesAS 4285:2019, 1.8

  • Smooth & uniform surfaces
  • Ensure that all jointing is finished with precision, to seamlessly match the adjoining surface