AS 3959:2018, H3 (a) AS 3959:2018, H3 (j) (iii) AS 3959:2018, H3 (a) BAL-FZ Certified
Eave Vents
AS 3959:2018, H3 (f) Industry Recommendation AS 3959:2018, H3 (d) AS 3959:2018, H3 (d) AS 3959:2018, H3 (e) Insulation AS 3959:2018, H3 (e)
Compress Oversized Mineral Wool Strips between Sheet Ends & under Ridge Cap ≥ 115mm thk ≥ 110mm (W)AS 3959:2018, 9.6.1 (c) Roof Mounted Evaporative Coolers
AS 3959:2018, H3 (c) AS 3959:2018, 9.6.3 (a) Tools™ Best Practice AS 3959:2018, H3 (h) AS 3959:2018, H3 (j) (iii) Tools™ Best Practice Exh aust Tools™ Best Practice
Cooking & Bathroom exhausts to Duct externally through Wall or Eaves to minimise condensation AS 3959:2018, H3 (d) Plywood
≥ 15mm T&G Plywood[1] Face Veneer perpendicular to Roof Structure Plywood Membrane RULES NCC 2022 V1 All Building Classes
NCC 2022 G5, H7D4, & S1
[2019 G5, 3.10.5, Sch 5]
May 2023
NCC 2022 Vol 1, G5 NCC 2022 Vol 2, H7D4 AS 3959:2018, H3 (a) Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCNCC 2022 Vol 1, G5 NCC 2022 Vol 2, H7D4 ≥ 15mm T&G Plywood Membrane continuously fixed over Timber or Steel Roof Structure atAS 3959:2018, H3 (a) ≥ 150mm CTS at the Panel End, &≥ 300mm CTS at Trusses & Intermediate Rafter≥ 10mm from Panel EdgeFace Veneer perpendicular to Roof Structure AS 3959:2018, H3 (a) Roofing Durability
AS 3959:2018, H3 (e) Industry Recommendation Insula tion AS 3959:2018, H3 (e)
Compressed Mineral Wool Strips ≥ 115mm thk≥ 110mm (W) Thickness may need to be reduced to be able to physically compress the Insulation under Roof Sheeting. Confirm acceptance with Certifying Authority prior to installation Industry Recommendation Wall & Floor BAL-FZ
AS 3959:2018, H3 (a) AS 3959:2018, H3 (e) AS 3959:2018, H3 (g) Z Flas hing AS 3959:2018, H3 (g)
40 x 40 x 40 x 0.55mm BMT ≥ 600mm Fixing centres along Eaves & into Plywood Ventilation
Screen all vents & outlets[1] High level ventilation at Gable Ends preferred [2] Ventilation RULES NCC 2022 V3 All Building Classes
NCC 2022 G5, H7D4, & S1
[2019 G5, 3.10.5, Sch 5]
May 2023
AS 3959:2018, 3.6.1 NCC 2022 Vol 1, G5 NCC 2022 Vol 2, H7D4 AS 3959:2018, 9.6.1 AS 3959:2018, 3.6.1 AS 3959:2018, 9.6.1 (b) Roof Sheet
0.42 to 0.6mm BMT [1] Junctions fully sealed[2] Non-combustible penetration sealed with Mineral Fibre[3] Sheet Roof MATERIALS NCC 2022 V4 All Building Classes
NCC 2022 G5, H7D4, & S1
[2019 G5, 3.10.5, Sch 5]
May 2023
AS 3959:2018, H3 (d) NCC 2022 Vol 1, G5 NCC 2022 Vol 2, H7D4 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCAS 3959:2018, H3 (d) NCC 2022 Vol 1, G5 0.42 to 0.6mm BMT NCC 2022 Vol 2, H7D4 Hex Head Screw (Self-drilling) Fixing with EPDM seal & Shank Guard On Battens, intervals at two corrugations On Roof Edge, on all corrugations Roofing RULES NCC 2022 V4 All Building Classes
NCC 2022 G5, H7D4, & S1
[2019 G5, 3.10.5, Sch 5]
May 2023
AS 3959:2018, 3.6.1 AS 3959:2018, 9.6.1 (a) AS 3959:2018, 9.6.1 (b) NCC 2022 Vol 1, G5 NCC 2022 Vol 2, H7D4 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCAS 3959:2018, 3.6.1 AS 3959:2018, 9.6.1 (a) Screen all gapsAS 3959:2018, 9.6.1 (b) , & the Roof to Wall & Roof to Roof junction be sealed byNCC 2022 Vol 1, G5 Fascia & Eaves lining, or Sealed on the junction between the top of the Wall & the Roof underside also between Rafters at the Wall line Ventilation OpeningsNCC 2022 Vol 2, H7D4 Fitted with non-combustible Ember Guards, or Protected by corrosion-resistant Mesh or Perforated Sheet Penetration RULES NCC 2022 V3 All Building Classes
NCC 2022 G5, H7D4, & S1
[2019 G5, 3.10.5, Sch 5]
May 2023
AS 3959:2018, 9.6.5 NCC 2022 Vol 1, G5 NCC 2022 Vol 2, H7D4 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCAS 3959:2018, 9.6.5 NCC 2022 Vol 1, G5 Seal openings with Fireproof Mineral Fiber, maintaining full function of penetrated elementsNCC 2022 Vol 2, H7D4 Use only non-combustible materials Rooflights, Ventilators & Pipes or Conduit to be AS 1530.8.2 compliant AS 3959:2018, H3 (d) AS 2419.1:2005, H3 (d) AS 3959:2018, 9.6.5 (a) Insulation
≥ 75mm Glasswool Blanket[1] Foil face down Glasswool Insulation RULES NCC 2022 V3 All Building Classes
NCC 2022 G5, H7D4, & S1
[2019 G5, 3.10.5, Sch 5]
May 2023
AS 3959:2018, H3 (c) NCC 2022 Vol 1, G5 NCC 2022 Vol 2, H7D4 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCAS 3959:2018, H3 (c) NCC 2022 Vol 1, G5 Use Glasswool Blanket that strictly adhere to the followingNCC 2022 Vol 2, H7D4 ≥ 75mm thk BAL-FZ Certified compressed Glasswool blanket withReflective Foil facing downwards fills the entire space between the Plywood Membrane & Sheet Roof ≥ 11kg/m³ Density≥ R 1.8 R-value AS 3959:2018, H3 (c) Gutter
Non-combustible materials[1] Gutter & Downpipes RULES NCC 2022 V6 All Building Classes
NCC 2022 G5, H7D4, & S1
[2019 G5, 3.10.5, Sch 5]
May 2023
AS 3959:2018, 9.6.7 NCC 2022 Vol 1, G5 NCC 2022 Vol 2, H7D4 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCAS 3959:2018, 9.6.7 NCC 2022 Vol 1, G5 Gutter & Downpipe installation NCC 2022 Vol 2, H7D4 Downpipe requirement not covered Non-combustible Gutter, Box Gutter & Valley Leaf Guards Box Gutter flashed at Roof junction with non-combustible materials AS 3959:2018, 9.6.7 Battens
Timber or Steel Top Hat Battens with fixings as required by site location tie-down[1] Battens RULES NCC 2022 V3 All Building Classes
NCC 2022 G5, H7D4, & S1
[2019 G5, 3.10.5, Sch 5]
May 2023
AS 3959:2018, H3 (b) NCC 2022 Vol 1, G5 NCC 2022 Vol 2, H7D4 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCAS 3959:2018, H3 (b) NCC 2022 Vol 1, G5 Install Battens as mandated by the site location's tie-down requirementsNCC 2022 Vol 2, H7D4 Timber Batten ≤ 45 x 90mm securely fastened to Plywood, adhering to AS 1684 , orSteel Top Hat Battens 40mm (H) & 0.55mm thk securely fastened to Plywood to Roof FramingAS 3959:2018, H3 (b) Timber or Steel Top Hat Battens with fixings as required by site location tie-downAS 3959:2018, H3 (b) Fascias
Construction of Fascia[1] System to AS 1530.8.2 ≥ 15mm Plywood≥ 16mm Fire Rated PlasterboardTimber Fascia Fascias MATERIALS NCC 2022 V4 All Building Classes
NCC 2022 G5, H7D4, & S1
[2019 G5, 3.10.5, Sch 5]
May 2023
AS 3959:2018, H3 (i) (i) AS 3959:2018, H3 (i) (ii) NCC 2022 Vol 1, G5 NCC 2022 Vol 2, H7D4 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCAS 3959:2018, H3 (i) (i) AS 3959:2018, H3 (i) (ii) Construct the Fascia using materials that strictly adhere to the followingNCC 2022 Vol 1, G5 ≥ 15mm Plywood Membrane installed on top of Timber, or Steel Truss Framing≥ 16mm Water & Fire-resistant Plasterboard fixed into Plywood with 38mm x 6g Screws @ 150mm CTS per AS/NZS 2588 6 to 10mm Joint spacing to fill with Fire-resistant SealantStagger Plywood joints when creating Butt Joints in the Plasterboard Timber Fascia fixed on Roof structure per AS 1684 NCC 2022 Vol 2, H7D4 AS 3959:2018, H3 (i) Construction of FasciaAS 3959:2018, H3 (i) System to AS 1530.8.2 ≥ 15mm Plywood≥ 16mm Fire Rated PlasterboardTimber Fascia Eaves
-/30/30 FRL or system to AS 1580.8.2 [1] Construction Materials[2] ≥ 15mm Plywood≥ 16mm Fire Rated Plasterboard≥ 4.5mm Fibre-cement Eave liningEaves RULES NCC 2022 V2 All Building Classes
NCC 2022 G5, H7D4, & S1
[2019 G5, 3.10.5, Sch 5]
May 2023
NCC 2022 Vol 1, G5 NCC 2022 Vol 2, H7D4 AS 3959:2018, 9.6.6 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCNCC 2022 Vol 1, G5 NCC 2022 Vol 2, H7D4 Eaves Lining InstallationAS 3959:2018, 9.6.6 -/30/30 FRL or system to AS 1580.8.2 Penetrations protected with a non-combustible material Ventilation openings fitted with Ember Guards Seal the Joints using either Plastic Joining Strips or Timber Storm Moulds Eaves RULES NCC 2022 V4 All Building Classes
NCC 2022 G5, H7D4, & S1
[2019 G5, 3.10.5, Sch 5]
May 2023
AS 3959:2018, 9.6.6 (c) (i) AS 3959:2018, 9.6.6 (d) AS 3959:2018, 9.6.6 (e) AS 3959:2018, 9.6.6 (f) Eaves MATERIALS NCC 2022 V4 All Building Classes
NCC 2022 G5, H7D4, & S1
[2019 G5, 3.10.5, Sch 5]
May 2023
AS 3959:2018, H3 (j) (i) AS 3959:2018, H3 (j) (ii) Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to NCC Specification 1, NCC Part G5, & AS 3959 ≥ 15mm Plywood installed on top of Timber, or Steel Truss Framing≥ 16mm Water & Fire-resistant Plasterboard fixed into Plywood with AS 3959:2018, H3 (j) (i) 38mm x 6g Screws @ 150mm CTS per AS/NZS 2588 ≥ 4.5mm Fibre-cement Eaves to protect the Plasterboard AS 3959:2018, H3 (j) (ii) Penetration RULES NCC 2022 V3 All Building Classes
NCC 2022 G5, H7D4, & S1
[2019 G5, 3.10.5, Sch 5]
May 2023
AS 3959:2018, 9.6.5 NCC 2022 Vol 1, G5 NCC 2022 Vol 2, H7D4 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCAS 3959:2018, 9.6.5 NCC 2022 Vol 1, G5 Seal openings with Fireproof Mineral Fiber, maintaining full function of penetrated elementsNCC 2022 Vol 2, H7D4 Use only non-combustible materials Rooflights, Ventilators & Pipes or Conduit to be AS 1530.8.2 compliant Penetration RULES NCC 2022 V4 All Building Classes
NCC 2022 G5, H7D4, & S1
[2019 G5, 3.10.5, Sch 5]
May 2023
AS 3959:2018, 9.6.5 (a) AS 3959:2018, 9.6.5 (a) AS 3959:2018, 9.6.5 (b) Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to NCC Specification 1, NCC Part G5, & AS 3959 Seal openings with Fireproof Mineral Fiber, maintaining full function of penetrated elementsAS 3959:2018, 9.6.5 (a) Use only non-combustible materialsAS 3959:2018, 9.6.5 (a) Rooflights, Ventilators & Pipes or Conduit to be AS 1530.8.2 compliantAS 3959:2018, 9.6.5 (b) Eaves MATERIALS NCC 2022 V3 All Building Classes
NCC 2022 G5, H7D4, & S1
[2019 G5, 3.10.5, Sch 5]
May 2023
AS 3959:2018, H3 (j) NCC 2022 Vol 1, G5 NCC 2022 Vol 2, H7D4 Building elements within Bushfire-prone Areas to be Bushfire Attack Resistant to the NCCAS 3959:2018, H3 (j) NCC 2022 Vol 1, G5 Eaves construction materialsNCC 2022 Vol 2, H7D4 ≥ 15mm Plywood installed on top of Timber, or Steel Truss Framing≥ 16mm Water & Fire-resistant Plasterboard fixed into Plywood with 38mm x 6g Screws @ 150mm CTS per AS/NZS 2588 ≥ 4.5mm Fibre-cement Eaves to protect the Plasterboard AS 3959:2018, 9.6.6 (c) (i) AS 3959:2018, H3 (j) Roof Construction BAL-FZ (Light Steel)