Fire Door Signage Building Codes & Rules


- Ensure signage compliance with our latest Tool™. Learn about placement, luminous contrast, durability, and often-overlooked wayfinding signage.


Fire Door & Hydrant

NCC 2022 Vol 1, S15C2 (a)

1.2mNCC 2022 Vol 1, S15C2 (a)

NCC 2022 Vol 1, S15C2 (b)

100NCC 2022 Vol 1, S15C2 (b)

Luminance Contrast

NCC 2022 Vol 1, S15C2 (b)

1.25mNCC 2022 Vol 1, S15C2 (b)

NCC 2022 Vol 1, S15C2 (a)

400NCC 2022 Vol 1, S15C2 (a)

NCC 2022 Vol 1, S15C2 (c)

50

to

300NCC 2022 Vol 1, S15C2 (c)

Single Line Tactile Characters Zone

Installation Zone

Industry Recommendation

1.5

RecommendedIndustry Recommendation

Architrave

NCC 2022 Vol 1, D4D7 (1) (a) (ii)

Fire Door Exit SignageNCC 2022 Vol 1, D4D7 (1) (a) (ii)

  • Provide exit doors with braille and tactile signs to ensure accessible navigation, they must display the ff:
  • Exit label, Floor Level & Identification

Door Signages


  • ≥ 30% luminance contrast between sign & wall[1]


Exit Wayfinding REQUIREMENTS


NCC 2022 V1


All Building Classes


NCC Vol 1 2022, S15C3, S15C4


May 2023



NCC 2022 Vol 1, S15C3

NSW Environmental Planning & Assessment Regulation 2000 , Division 7 (183)

Braille & Tactile SignageNCC 2022 Vol 1, S15C3

  • 1 to 1.5mm embossed tactile characters
  • 2 to 7mm stroke thickness
  • Text Height
  • Upper case
  • 15 to 55mm
  • 20 to 55mm for exit signs on doors
  • Lower case
  • ≥ 50% of upper case height
  • Spacing
  • ≥ 2mm Letter
  • ≥ 10mm Word
  • All characters, symbols, and sign edges, including frames, must be rounded
  • Background and text must have a matt or low-sheen finish
  • Text alignment must be left justified and use the Arial typeface
  • Single words may be centered

NSW Fire Safety Notice SignageNSW Environmental Planning & Assessment Regulation 2000 , Division 7 (183)

  • Informs people that blocking, interfering with, or removing the notice is an offense under fire safety laws
  • In compliance with Environmental Planning & Assessment Regulation 2000

NCC 2022 Vol 1, S15C4 (b)

Emergency & Exit Lighting

Door Compliance Tagging

Leaf Signage


  • Always visible location[1]
  • ≥ 20mm tall font, CAPITALISED, in contrasting colour
  • Signage on both leaves of double swing Doors


Signage RULES


NCC 2022 V1


Class 2 to 9


NCC 2022 D3D28 [2019 D2.23]


May 2023



NCC 2022 Vol 1, D3D28 (1)

NCC 2022 Vol 1, D3D28 (4)

NCC 2022 Vol 1, D3D28 (2)

NCC 2022 Vol 1, D3D28 (3)

FIRE SAFETY DOOR

DO NOT OBSTRUCT

DO NOT KEEP OPEN

  • If door has a hold open device or is a door discharging from a fire -isolated exit

FIRE SAFETY DOOR

DO NOT OBSTRUCT

  • Signage not required for a Class 2, 3 or 4 Sole Occupancy Unit

NCC 2022 Vol 1, D3D28

  • Always visible locationNCC 2022 Vol 1, D3D28
  • ≥ 20mm tall font, CAPITALISED, in contrasting colour
  • Signage on both leaves of double swing Doors
Redirecting... (5)
Please wait while we redirect you to the correct page.