NCC 2022 HP, 9.2.3 (2) (a) NCC 2022 HP, 9.2.3 (3) (a) NCC 2022 HP, 9.2.6 Protection of External Walls NCC 2022 HP, 9.2.6
≥ 1.8m maintained distance to Setback, or Separation, or 60/60/60 FRL Construction to[A ] Setback, or [B ] Class 10a Wall, or [C ] Class 1 Wall NCC 2022 HP, 9.2.3 (1) (a) NCC 2022 HP, 9.2.3 (2) NCC 2022 HP, 9.2.3 (3) (b) NCC 2022 HP, 9.2.3 (3) (a) Fire Resisting Wall Construction < 1.8m
NCC 2022 HP, 9.2.10 Combustible Roof Lights NCC 2022 HP, 9.2.10
≥ 1.8m from neighbouring roof lights≤ 20% of entire roof area NCC 2022 HP, 9.2.9 (3) NCC 2022 HP, 9.2.9 (3) NCC 2022 HP, 9.2.9 (4) Allowable Encroachments
< 1.8m NCC 2022 HP, 9.2.9 (3) Utility meters, Light fittings, Antennas Sun blinds, Water tanks, Pergolas ≤1m (H) L andings, Open platforms, Access ways≥ 900mm NCC 2022 HP, 9.2.9 (4) Residential fuel tanks, Flues, Pipes Heating or cooling devices NCC 2022 HP, 9.2.6 Adjacent Building on Same Allotment
NCC 2022 HP, 9.2.9 (4) NCC 2022 HP, 9.2.6 NCC 2022 HP, 9.2.3 (4) Window FRL exemption ≥ 1.2m from Boundary NCC 2022 HP, 9.2.3 (4)
≤ 1.2m² Bathroom, Laundry or WC≤ 0.54m² Non-openable roomsSteel framed, Wired Glass, or Hollow Glass Blocks Adjacent Building on Same Allotment
NCC 2022 HP, 9.2.2 Building at Property Boundary
NCC 2022 HP, 9.2.1 (b) NCC 2022 HP, 9.2.9 (4) Fire Separation Carports
≥ 2 Open Sides[1] ≥ 2/3 Open PerimeterFire Separation Carport RULES NCC 2022 V1 All Building Classes
NCC 2022 HP 9.2.8 [2019: 3.7.2.6]
May 2023
NCC 2022 HP, 9.2.8 NCC 2022 HP, 9.2.8 (b) NCC 2022 HP, 9.2.8 (f) NCC 2022 HP, 9.2.8 (f) (i) NCC 2022 HP, 9.2.8 (f) (ii) NCC 2022 HP, 9.2.8 (c) NCC 2022 HP, 9.2.8 (c) NCC 2022 HP, 9.2.8 (a) Redirecting... (5)