Spreaders
≥ 1.8m beyond spreader [1] [2] Seal side laps to corrugated Roof Sheets Fully sark Tiled Roofs Extend foot of DP to keep clear of Flashing [3] 1/2 Cap Ends for cleaning [4] Spreader RULES NCC 2022 V2 All Building Classes
NCC 2022 3.3.5, F1P3, F1D3 [2019 3.1.3.5, FP1.3, F1.1]
May 2023
HB 39:2015, 5.7.7 HB 39:2015, 5.7.7 HB 39:2015, 5.7.7 HB 39:2015, 5.7.7 (g) NCC 2022 HP, 3.3.5 AS/NZS 3500.3:2021, 1 Stormwater Drainage installed to NCC & AS/NZS 3500.3HB 39:2015, 5.7.7 HB 39:2015, 5.7.7 Catchment area of both upper & lower Roof must not exceed Manufacturer's Design Carrying Capacity for the lower Roof Water to be discharged in direction of Roof FallHB 39:2015, 5.7.7 Extend Foot of Downpipe to ensure Spreader is clear of FlashingsHB 39:2015, 5.7.7 (g) Must not discharge above ValleysNCC 2022 HP, 3.3.5 Corrugated Roof Sheets AS/NZS 3500.3:2021, 1 ≥ 1.8m each side from Spreader to be Sealed at Laps for full sheet length Tiled Roof ≥ 1.8m each side from Spreader to be Sarked & turned into the Gutter HB 39:2015, 5.7.7 (a) HB 39:2015, 5.7.7 (b) HB 39:2015, 5.7.7 HB 39:2015, 5.7.7 (f) HB 39:2015, 5.6 Eaves Gutter HB 39:2015, 5.6
≥ 1.2m Bracket spacing≤ 20m Expansion Joint spacing HB 39:2015, 5.7.7 (b) HB 39:2015, 5.7.7 (a) HB 39:2015, 5.7.6 (d) HB 39:2015, 5.7.7 (b) HB 39:2015, 5.7.7 (a) HB 39:2015, 5.6 (f) AS/NZS 3500.3:2021, 4.5.3 (a) HB 39:2015, 5.3.2 (k) AS/NZS 3500.3:2018, 4.7.2.3 Industry Recommendation Stormwater Connection
Downpipe with Direct Connection[1] ≥ 75mm unsealed slip joint≤ 2m from point of entry to Stormwater DrainOpen Connection[2] ≥ 40mm clear above grateStormwater Connection TYPES NCC 2022 V5 All Building Classes
NCC 2022 F1P3, F1D3 [2019 FP1.3, F1.1]
May 2023
NCC 2022 HP, 3.3.5 EFSG 2.0 EFSG 2.0 Informative Stormwater Drainage installed to NCCNCC 2022 HP, 3.3.5 Rainwater Drainage Systems must convey Rainwater to an Outfall & avoid surface water damaging the BuildingEFSG 2.0 5% AEPEFSG 2.0 Percentage chance of a specific rainfall amount (intensity or depth) occurring in a year Surface water must not enter the Building 1% A EPHardstand & Precast OutletInformative EFSG (NSW Public School) compliant 30° splayed end 40mm clearance Screw fixed Grate Direct Connection Residential / Cottage construction Fall Finished Ground away from Building Outlet SUPPLIERS NCC 2022 V2 Suitable Products for this use (equal to's allowed) Galvin Engineering Concrete Downpipe Sump Box ≥ 150mm Ø Outlet Screw fixed Grate Others? Please send feedback HB 39:2015, 5.7.6 (g) EFSG 2.0 Downpipe with Direct ConnectionHB 39:2015, 5.7.6 (g) ≥ 75mm unsealed slip joint≤ 2m from point of entry to Stormwater DrainOpen ConnectionEFSG 2.0 ≥ 40mm clear above grate Redirecting... (5)