Construction Joint (Termite Management) Building Codes & Rules


- Construction Joint Tools™ simplifies the National Construction Code (NCC) with interactive graphics, including deemed to comply & best practices.


Fall

Contruction Joint

Natural

Surface

Informative

Infill SlabsInformative

  • Physical barrier across joint

Informative

WallsInformative

  • Avoid bottom plate fixings through barrier

Weephole

Industry Recommendation

Timber Floor JunctionsIndustry Recommendation

  • Maximise clearance without eroding slab edge or footing
  • In low clearance or moist conditions
  • Maximise ventilation
  • Polyethene membrane over soil

Slab On

Ground

Timber

Floor

Fall

Paved

Surface

Infill

Slab

Slab Edge

Termite Management

Termite Management


  • Termite control required for Ground Level floor junctions[1]
  • ≥ 75mm Wall exposure between ground level & Termite Sheet, to allow visual detection of Termites[2]


Durable Notice RULES


NCC 2022 V1


All Building Classes


NCC 2022, 3.4.3


May 2023



NCC 2022 HP, 3.4.3

NCC 2022 HP, 3.4.3

NCC 2022 HP, 3.4.3 (a)

NCC 2022 HP, 3.4.3 (b)

NCC 2022 HP, 3.4.3 (c)

NCC 2022 HP, 3.4.3 (d)

Termite RISK


NCC 2022 V1


All Building Classes


NCC 2022, H1D3 & 3.4.1 [2019 3.1.4.2]


May 2023



NCC 2022 HP, 3.4.1 (1) (a)

NCC 2022 HP, 3.4.1 (1) (b)

NCC 2022 HP, 3.4.1(2)

  • Termite Management System Required if
  • Location is identified at Risk of Attack, &NCC 2022 HP, 3.4.1 (1) (a)
  • Any Primary Building Element is susceptibleNCC 2022 HP, 3.4.1 (1) (b)
  • Primary Building Elements are
  • Any member designed to take Loads
  • Wall, Roof, Ceiling, Floor, Ramp or Stair Framing
  • Any bracing or other framing members
  • Materials not susceptible to attackNCC 2022 HP, 3.4.1(2)
  • Metals
  • Concrete
  • Masonry
  • Fibre-reinforced Concrete
  • Naturally resistant Timber
  • Preservative-treated Timber

AS 3660.1:2014, 4.4

AS 3660.1:2014, 4.3.2.2

AS 3660.1:2014, 6.3.2

≥ 150AS 3660.1:2014, 6.3.2

AS 3660.1:2014, 4.4

≥ 75AS 3660.1:2014, 4.4

AS 3660.1:2014, 3.3.2 (b)

≥ 150AS 3660.1:2014, 3.3.2 (b)

AS 3660.1:2014, D2 (b)

Redirecting... (5)
Please wait while we redirect you to the correct page.