Concentrated Load
- Centred beneath steel Column[1]
- SL72 reinforcement[2]
Localised Thickening RULES
NCC 2022 V1
All Building Classes
NCC 2022, 4.2.20
May 2023
NCC 2022 HP, 4.2.20 (b)
NCC 2022 HP, 4.2.20 (c)
NCC 2022 HP, 4.2.20 (a) (i)
NCC 2022 HP, 4.2.20 (a) (ii)
NCC 2022 HP, 4.2.20 (b)
NCC 2022 HP, 4.2.20 (c)
NCC 2022 HP, 4.2.14
AS 2870:2011, 3.2.3
AS 2870:2011, 3.2.3
NCC 2022 HP, 4.2.14
AS 2870:2011, 3.2.3
NCC 2022 HP, 4.2.14
AS 2870:2011, 3.2.3
NCC 2022 HP, 4.2.14
AS 2870:2011, 3.2.3
NCC 2022 HP, 4.2.14
AS 2870:2011, 3.2.3
NCC 2022 HP, 4.2.14
AS 2870:2011, 3.2.3
NCC 2022 HP, 4.2.14
AS 2870:2011, 3.2.3
NCC 2022 HP, 4.2.14
AS 2870:2011, 3.2.3
Soil Class A, S or M Only
AS 2870:2011, 3.2.3
AS 3660.1:2014, 4.4
NCC 2022 HP, 4.2.14
AS 2870:2011, 3.2.3
NCC 2022 HP, 4.2.14
AS 2870:2011, 3.2.3
NCC 2022 HP, 4.2.14
AS 2870:2011, 3.2.3
NCC 2022 HP, 4.2.14
AS 2870:2011, 3.2.3
Concrete Slab Insulation
- Under Slab ≥ R2.0[1]
- Slab Edges ≥ R1.0[2]
Concrete Slab on Ground RULES
NCC 2022 V7
Class 1 & 10a
NCC 2022 HP13.2.6 [2019: 3.12.1.5]
May 2023
NCC 2022 HP, 13.2.6 (5) (b) (ii)
NCC 2022 HP, 13.2.6 (5) (b) (i)
NCC 2022 HP, 13.2.6 (4)
NCC 2022 HP, 13.2.6 (6) (a)
NCC 2022 HP, 13.2.6 (6) (b) (i)
NCC 2022 HP, 13.2.6 (5) (b) (ii)
NCC 2022 HP, 13.2.6 (5) (b) (i)
Slab Edge Reinforcement
Slab Edge Reinforcement
NCC 2022 V1
NCC 2022 HP, 4.2.11 (7) (e)
NCC 2022 HP, 4.2.11 (7) (a)
NCC 2022 HP, 4.2.11 (7) (d)
Concrete Benchmark
Termite Management
- Termite control required for Ground Level floor junctions
- ≥ 75mm slab exposure above the external finished floor level to allow easy detection of termites[1]
Durable Notice RULES
NCC 2022 V1
All Building Classes
NCC 2022, 3.4.3
May 2023
NCC 2022 HP, 3.4.3
NCC 2022 HP, 3.4.3
NCC 2022 HP, 3.4.3 (a)
NCC 2022 HP, 3.4.3 (b)
NCC 2022 HP, 3.4.3 (c)
NCC 2022 HP, 3.4.3 (d)
Termite RISK
NCC 2022 V3
Class 1 & 10
NCC 2022, H1D3 & HP3.4.1 [2019 3.1.4.2]
May 2023
NCC 2022 HP, 3.4.1(2)
NCC 2022 HP, 3.4.1 (1) (b)
NCC 2022 HP, 3.4.1
- Termite Management System Required ifNCC 2022 HP, 3.4.1(2)
- Location is identified at Risk of Attack, &
- Any Primary Building Element is susceptible
- Primary Building Elements areNCC 2022 HP, 3.4.1 (1) (b)
- Any member designed to take Loads
- Wall, Roof, Ceiling, Floor, Ramp or Stair Framing
- Any bracing or other framing members
- Materials not susceptible to attackNCC 2022 HP, 3.4.1
- Metals
- Concrete
- Masonry
- Fibre-reinforced Concrete
- Naturally resistant Timber
- Preservative-treated Timber
Termite MANAGEMENT
NCC 2022 V5
Class 1 & 10
NCC 2022 H1D3 & HP3.4.2 [2019 3.1.4.3]
May 2023
NCC 2022 HP, 3.4.2
AS 3660.1:2014, 4.4
NCC 2022 Vol 2, H1D3
AS 3660.1:2014, 4.4
- Termite control required for Ground Level floor junctions
- ≥ 75mm slab exposure above the external finished floor level to allow easy detection of termitesAS 3660.1:2014, 4.4
Concrete Cover
- ≥ 30mm over membrane[1]
- ≥ 40mm unprotected ground[2]
- ≥ 20mm internal surface[3]
- ≥ 40mm external exposure[4]
Concrete COVER
NCC 2022 V5
All Building Classes
NCC 2022 4.2.11 [2019 3.2.3.2]
May 2023
AS 3600:2018, 4.10.3.2
AS 3600:2018, 4.3.1 (c)
NCC 2022 HP, 4.2.11
NCC 2022 HP, 4.2.11 (5) (b)
NCC 2022 HP, 4.2.11 (5) (a)
NCC 2022 HP, 4.2.11 (5) (c)
NCC 2022 HP, 4.2.11 (5) (d)
Beam Layout
- Integral structural grid form[1]
- Reinforcement for Edge & Internal Beam [2]
- Varies based on Site Class (A, S, or M)
Beam Layout RULES
NCC 2022 V4
All Building Classes
NCC 2022 HP4.2.14
May 2023
NCC 2022 HP, 4.2.14
NCC 2022 HP, 4.2.14
AS 2870:2011, 5.3.9
NCC 2022 HP, 4.2.14
AS 2870:2011, 3.2.3
NCC 2022 HP, 4.2.14
NCC 2022 HP, 4.2.14
NCC 2022 HP, 4.2.14
Edge Rebate
Slab Reinforcement
- ≤ 800mm CTS bar chairs spacing[1]
- Firmly fixed & supported off the ground[2]
- Wire chairs with concrete cover & placed on flat bases [3]
Reinforcement Mesh Overlapping RULES
NCC 2022 V1
AS 2870:2011, 5.3.2 (c)
- Proper Overlap Trench mesh (Mesh A & B)AS 2870:2011, 5.3.2 (c)
- Acceptable Overlapping
- ≥ 2 bars staggered overlap
- Avoids weak spot & distributes load better
- Unacceptable Overlapping
- Overlapped exactly on top of each other with matching bar ends & joints
- Causes stress concentration at one point & can lead to failure
Reinforcement RULES
NCC 2022 V4
All Building Classes
NCC 2022 HP4.2.16 [2019:3.2.5.5]
May 2023
AS 2870:2011, 3.3
AS 2870:2011, 3.3
- Class A & S Slab Reinforcement as followsAS 2870:2011, 3.3
- SL82 for Slab ≥ 25m & < 30m
- SL72 for Slab ≥ 18m & < 25m
- SL62 for Slab > 12m & < 18m
- SL63 for Slab ≤ 12m
- For Western Australia, with Slabs length < 25m, thickness can be reduced to 85mm with Slab Reinforcement as followsAS 2870:2011, 3.3
- SL62 for Slab ≥ 18m & < 25m
- SL63 for Slab > 12m & < 18m
- SL53 for Slab ≤ 12m
NCC 2022 HP, 4.2.11 (7) (e)
NCC 2022 HP, 4.2.11 (7) (a)
NCC 2022 HP, 4.2.11 (7) (d)
Recessed Slab
- Recess depth ≤ Slab thickness
- ≥ 400mm lap length[1]
- Recess depth ≥ Slab thickness
- ≥ 400mm Steel mesh overlap[2]
Recess Depth RULES
NCC 2022 V3
All Building Classes
NCC 2022 HP4.2.22
May 2023
NCC 2022 HP, 4.2.22 (1) (a)
NCC 2022 HP, 4.2.22 (1) (b) (i)
NCC 2022 HP, 4.2.22 (1) (b) (ii)
NCC 2022 HP, 4.2.22 (1) (a)
NCC 2022 HP, 4.2.22 (1) (b) (i)
AS 2870:2011, 3.5.4
NCC 2022 HP, 4.2.14
AS 2870:2011, 3.2.3