Footing Slab Building Codes & Rules


- Footing Slab Tools™ simplifies the National Construction Code (NCC) with interactive graphics, including deemed to comply & best practices.


Slab Thickening

Vapour

Barrier

Edge Rebate

Slab Thickening

NCC 2022 HP, 4.2.11 (5) (b)

NCC 2022 HP, 4.2.11 (5) (c)

NCC 2022 HP, 4.2.11 (5) (d)

NCC 2022 HP, 4.2.11 (5) (a)

Concrete Cover

NCC 2022 HP, 4.2.16

AS 2870:2011, 3.3 (a)

300NCC 2022 HP, 4.2.16AS 2870:2011, 3.3 (a)

AS 2870:2011, 3.3 (b)

100AS 2870:2011, 3.3 (b)

Unreinforced Edge Footing

Loadbearing Wall

Loadbearing Wall

Brick Veneer

Fully Sarked

Brick Veneer

Slab on Ground

Vapour Barrier

Concrete to concrete contact between Footing & Slab

AS 2870:2011, 3.3 (b)

Engaged Pier

AS 2870:2011, 3.3 (a)

Unreinforced Footing SlabAS 2870:2011, 3.3 (a)

  • Ideal for flat sites, no connection between Footing & Slab
  • For Class A sites
  • Dune sands may require compaction

NCC 2022 HP, 4.2.16

AS 2870:2011, 3.3 (a)

50NCC 2022 HP, 4.2.16AS 2870:2011, 3.3 (a)

NCC 2022 HP, 4.2.16

AS 2870:2011, 3.3 (a)

170NCC 2022 HP, 4.2.16AS 2870:2011, 3.3 (a)

NCC 2022 HP, 4.2.16 (b)

NCC 2022 HP, 4.2.16 (a)

NCC 2022 HP, 4.2.16 (e)

NCC 2022 HP, 4.2.16 (d)

NCC 2022 HP, 4.2.16 (c)

Site Class A & S suitable for

Soil

Alternative Edge Beam Treatment

NCC 2022 HP, 4.2.16

AS 2870:2011, 3.3 (a)

200NCC 2022 HP, 4.2.16AS 2870:2011, 3.3 (a)

NCC 2022 HP, 4.2.16

AS 2870:2011, 3.3 (a)

300NCC 2022 HP, 4.2.16AS 2870:2011, 3.3 (a)

NCC 2022 HP, 4.2.16

AS 2870:2011, 3.3 (a)

100NCC 2022 HP, 4.2.16AS 2870:2011, 3.3 (a)

NCC 2022 HP, 4.2.16

AS 2870:2011, 3.3 (a)

50NCC 2022 HP, 4.2.16AS 2870:2011, 3.3 (a)

AS 2870:2011, 3.3 (b)

500AS 2870:2011, 3.3 (b)

Concrete Benchmark

Termite Management


  • Termite control required for Ground Level floor junctions
  • ≥ 75mm slab exposure above the external finished floor level to allow easy detection of termites[1]


Termite MANAGEMENT


NCC 2022 V5


Class 1 & 10


NCC 2022 H1D3 & HP3.4.2 [2019 3.1.4.3]


May 2023



NCC 2022 HP, 3.4.2

AS 3660.1:2014, 4.4

NCC 2022 Vol 2, H1D3

  • Termite Management compliant to the NCCNCC 2022 HP, 3.4.2
  • Inspection ZoneAS 3660.1:2014, 4.4NCC 2022 Vol 2, H1D3
  • ≥ 75mm exposed Concrete Face
  • Smooth surface, free of Ripples or Honeycombing
  • Tiling, Render, Vapour Barrier, Flashings, Structures & the like, not allowed to bridge this Zone

AS 3660.1:2014, 4.4

  • Termite control required for Ground Level floor junctions
  • ≥ 75mm slab exposure above the external finished floor level to allow easy detection of termitesAS 3660.1:2014, 4.4

AS 3660.1:2014, 4.4

≥ 75AS 3660.1:2014, 4.4

Concentrated Load


  • Centered under steel Column[1]
  • SL72 reinforcement[2]


Localised Thickening RULES


NCC 2022 V3


All Building Classes


NCC 2022, 4.2.20


May 2023



NCC 2022 HP, 4.2.20 (b)

NCC 2022 HP, 4.2.20 (c)

NCC 2022 HP, 4.2.20 (a) (i)

NCC 2022 HP, 4.2.20 (a) (ii)

NCC 2022 HP, 4.2.20 (b)

NCC 2022 HP, 4.2.20 (c)

NCC 2022 HP, 4.2.16

AS 2870:2011, 3.3 (a)

150NCC 2022 HP, 4.2.16AS 2870:2011, 3.3 (a)

NCC 2022 HP, 4.2.16

AS 2870:2011, 3.3 (a)

280NCC 2022 HP, 4.2.16AS 2870:2011, 3.3 (a)

AS 2870:2011, 3.3 (b)

150AS 2870:2011, 3.3 (b)

Slab Reinforcement


  • ≤ 800mm CTS bar chairs spacing[1]
  • Firmly fixed & supported off the ground[2]
  • Wire chairs with concrete cover & placed on flat bases [3]


Reinforcement RULES


NCC 2022 V3


All Building Classes


NCC 2022 HP4.2.16 [2019:3.2.5.5]



May 2023



AS 2870:2011, 3.3

AS 2870:2011, 3.3

  • Class A & S Slab Reinforcement as followsAS 2870:2011, 3.3
  • SL82 for Slab ≥ 25m & < 30m
  • SL72 for Slab ≥ 18m & < 25m
  • SL62 for Slab > 12m & < 18m
  • SL63 for Slab ≤ 12m


  • For Western Australia, with Slabs length < 25m, thickness can be reduced to 85mm with Slab Reinforcement as followsAS 2870:2011, 3.3
  • SL62 for Slab ≥ 18m & < 25m
  • SL63 for Slab > 12m & < 18m
  • SL53 for Slab ≤ 12m

NCC 2022 HP, 4.2.11 (7) (e)

NCC 2022 HP, 4.2.11 (7) (a)

NCC 2022 HP, 4.2.11 (7) (d)

Concrete Slab


  • Under Slab R ≥ 2.0[1]
  • Slab Edges R ≥ 1.0[2]


Concrete Slab on Ground RULES


NCC 2022 V7


Class 1 & 10a


NCC 2022 HP13.2.6 [2019: 3.12.1.5]


May 2023



NCC 2022 HP, 13.2.6 (5) (b) (ii)

NCC 2022 HP, 13.2.6 (5) (b) (i)

NCC 2022 HP, 13.2.6 (4)

NCC 2022 HP, 13.2.6 (6) (a)

NCC 2022 HP, 13.2.6 (6) (b) (i)

NCC 2022 HP, 13.2.6 (5) (b) (ii)

NCC 2022 HP, 13.2.6 (5) (b) (i)

Recessed Slab


  • Recess depth Slab thickness
  • ≥ 400mm lap length[1]
  • Recess depthSlab thickness
  • ≥ 400mm Steel mesh overlap[2]


Recess Depth RULES


NCC 2022 V1


All Building Classes


NCC 2022 HP4.2.22


May 2023



NCC 2022 HP, 4.2.22 (1) (a)

NCC 2022 HP, 4.2.22 (1) (b) (i)

NCC 2022 HP, 4.2.22 (1) (b) (ii)

NCC 2022 HP, 4.2.22 (1) (a)

NCC 2022 HP, 4.2.22 (1) (b) (i)