AS 3660.1:2014, 4.4
AS 2870:2011, 5.3.4
AS 3660.1:2014, 4.4
AS 3660.1:2014, 4.4
AS 2870:2011, 5.3.4 (b)
FitmentsAS 2870:2011, 5.3.4 (b)
- Allow reduction in horizontal thickness
- R10 or N10 Cranked Bar
- ≤ 900mm spacing
- ≥ 200mm thk not required
AS 2870:2011, 5.3.4
AS 2870:2011, 5.3.4
AS 3660.1:2014, 4.4
AS 3660.1:2014, 5.3.8.2
AS 3660.1:2014, 5.3.8.2
AS 3700:2018, 4.7.2
AS 2870:2011, 5.3.4 (b)
AS 3660.1:2014, 4.4
AS 2870:2011, 5.3.4
AS 2870:2011, 5.3.4 (f)
AS 2870:2011, 5.3.4 (c)
AS 2870:2011, 5.3.4
NCC 2022 HP, 4.2.9 (a)
AS 2870:2011, 5.3.4 (f)
AS 2870:2011, 5.3.4 (b)
AS 2870:2011, 5.3.4 (c)
Vapour Barrier
- Continuous under Beams & Pods[1]
- Turn up to Ground Level at Slab Edges[2]
- Protect from & repair any punctures[3]
Moisture Control
NCC 2022 V1
All Building Classes
NCC 2022, F1D7 & Part 4.2.8 [2019 F1.10, 3.2.2.6]
May 2023
AS 2870:2011, 5.3.3.2 (a)
AS 2870:2011, 5.3.3.2 (a) (i)
AS 2870:2011, 5.3.3.2 (a) (ii)
AS 2870:2011, 5.3.3.4 (b)
AS 2870:2011, 5.3.3.4 (a)
AS 2870:2011, 5.3.3.4 (c)
NCC 2022 HP, 4.2.8
NCC 2022 Vol 1, F1D7
AS 2870:2011, 5.3.3.4 (a)
AS 2870:2011, 5.3.3.4 (a)
AS 2870:2011, 5.3.3.3 (c)
Concrete Benchmark
Concrete Cover
- ≥ 30mm over membrane[1]
- ≥ 40mm unprotected ground[2]
- ≥ 20mm internal surface[3]
- ≥ 40mm external exposure[4]
Concrete COVER
NCC 2022 V5
All Building Classes
NCC 2022 4.2.11 [2019 3.2.3.2]
May 2023
AS 3600:2018, 4.10.3.2
AS 3600:2018, 4.3.1 (c)
NCC 2022 HP, 4.2.11
NCC 2022 HP, 4.2.11 (5) (b)
NCC 2022 HP, 4.2.11 (5) (a)
NCC 2022 HP, 4.2.11 (5) (c)
NCC 2022 HP, 4.2.11 (5) (d)
Termite Management
- Termite control required for Ground Level floor junctions
- ≥ 75mm slab exposure above the external finished floor level to allow easy detection of termites[1]
Durable Notice RULES
NCC 2022 V1
All Building Classes
NCC 2022, 3.4.3
May 2023
NCC 2022 HP, 3.4.3
NCC 2022 HP, 3.4.3
NCC 2022 HP, 3.4.3 (a)
NCC 2022 HP, 3.4.3 (b)
NCC 2022 HP, 3.4.3 (c)
NCC 2022 HP, 3.4.3 (d)
Termite RISK
NCC 2022 V3
Class 1 & 10
NCC 2022, H1D3 & HP3.4.1 [2019 3.1.4.2]
May 2023
NCC 2022 HP, 3.4.1(2)
NCC 2022 HP, 3.4.1 (1) (b)
NCC 2022 HP, 3.4.1
- Termite Management System Required ifNCC 2022 HP, 3.4.1(2)
- Location is identified at Risk of Attack, &
- Any Primary Building Element is susceptible
- Primary Building Elements areNCC 2022 HP, 3.4.1 (1) (b)
- Any member designed to take Loads
- Wall, Roof, Ceiling, Floor, Ramp or Stair Framing
- Any bracing or other framing members
- Materials not susceptible to attackNCC 2022 HP, 3.4.1
- Metals
- Concrete
- Masonry
- Fibre-reinforced Concrete
- Naturally resistant Timber
- Preservative-treated Timber
Termite MANAGEMENT
NCC 2022 V5
Class 1 & 10
NCC 2022 H1D3 & HP3.4.2 [2019 3.1.4.3]
May 2023
NCC 2022 HP, 3.4.2
AS 3660.1:2014, 4.4
NCC 2022 Vol 2, H1D3
AS 3660.1:2014, 4.4
- Termite control required for Ground Level floor junctions
- ≥ 75mm slab exposure above the external finished floor level to allow easy detection of termitesAS 3660.1:2014, 4.4
Concrete Mix
- N20 Grade to AS 1379[1]
- ≥ 20 Mpa strength at 28 days[2]
- ≤ 20mm aggregate size[3]
- 100mm slump[4]
- Properly compacted[5]
Concrete Mix RULES
NCC 2022 V4
All Building Classes
NCC 2022, 4.2.10 [2019 3.2.3.1]
May 2023
NCC 2022 HP, 4.2.10
- Concrete to comply with NCCNCC 2022 HP, 4.2.10
- Mixing & Delivery
- ≤ 1 ½ hrs complete discharge from Concrete truck upon Cement hydration unless a retarder is used
- Compaction by vibration
- To remove air pockets
- Improve contact with Reinforcement & Formwork
- Enhance durability
- Avoid over-vibrating
- Slab Edges
- Proper finishing & curing of edges improves resistance to moisture damage
- Chemical Curing
- Determine if surface finish adhesive to be used is compatible with chemical curing methods
NCC 2022 HP, 4.2.10 (a) (i)
NCC 2022 HP, 4.2.10 (a) (ii)
NCC 2022 HP, 4.2.10 (a) (iii)
NCC 2022 HP, 4.2.10 (c)
AS 2870:2011, 5.3.1