Waffle Raft Slab Building Codes & Rules


- Waffle Raft Tools™ simplifies the National Construction Code (NCC) with interactive graphics, including deemed to comply & best practices.


Sand Blinding

Edge Beam

Pier

Waffle Pod

AS 2870:2011, 3.4.1

≤ 1.09mAS 2870:2011, 3.4.1

Vapour Barrier

Finished Concrete Floor Level

Timber Frame

Waffle Pod

Waffle Pod

AS 3660.1:2014, 4.4

≥ 75AS 3660.1:2014, 4.4

AS 2870:2011, 3.4.2

110AS 2870:2011, 3.4.2

AS 2870:2011, 3.4.1

≥ 300AS 2870:2011, 3.4.1

AS 2870:2011, 3.4.1

20AS 2870:2011, 3.4.1

AS 2870:2011, 3.4.1

DAS 2870:2011, 3.4.1

Masonry Veneer

Loadbearing Wall

Full Sarking

Clad Frame

Flashing

Soil

- copy

Soil

Loadbearing Wall

AS 2870:2011, 3.4.2

150AS 2870:2011, 3.4.2

AS 2870:2011, 3.4.1

≤ 1.09mAS 2870:2011, 3.4.1

≥ 450

AS 2870:2011, 3.4.1

85AS 2870:2011, 3.4.1

AS 2870:2011, 3.4.2

110AS 2870:2011, 3.4.2

Pier


  • For M or H Sites[1]
  • Each 3rd internal Beam intersection[2]


Pier RULES


NCC 2022 V1


All Building Classes


NCC 2022 H1D4 & 4.2 [2019 3.2]



May 2023



AS 2870:2011, 3.4.5

AS 2870:2011, 3.4.5 (a)

AS 2870:2011, 3.4.5 (b)

AS 2870:2011, 3.4.5 (b)

AS 2870:2011, 3.4.5 (a)

AS 2870:2011, 3.4.5

Concrete Mix


  • N20 Grade to AS 1379[1]
  • ≥ 20 Mpa strength at 28 days[2]
  • ≤ 20mm aggregate size[3]
  • 100mm slump[4]
  • Properly compacted[5]


Concrete Mix RULES


NCC 2022 V3


All Building Classes


NCC 2022, 4.2.10 [2019 3.2.3.1]



May 2023



NCC 2022 HP, 4.2.10

  • Construction of Footings & Slabs to comply with NCC Part 4.2, AS 2870, & AS 3600
  • Concrete to AS 3600NCC 2022 HP, 4.2.10
  • Mixing & Delivery
  • ≤ 1 ½ hrs complete discharge from Concrete truck upon Cement hydration unless a retarder is used
  • Compaction by vibration
  • To remove air pockets
  • Improve contact with Reinforcement & Formwork
  • Enhance durability
  • Avoid over-vibrating
  • Slab Edges
  • Proper finishing & curing of edges improves resistance to moisture damage
  • Chemical Curing
  • Determine if surface finish adhesive to be used is compatible with chemical curing methods

NCC 2022 HP, 4.2.10 (a) (i)

NCC 2022 HP, 4.2.10 (a) (ii)

NCC 2022 HP, 4.2.10 (a) (iii)

NCC 2022 HP, 4.2.10 (c)

AS 2870:2011, 5.3.1

Masonry Veneer

Concrete Benchmark

Vapour Barrier


  • Continuous under Beams & Pods[1]
  • Turn up to Ground Level at Slab Edges[2]
  • Protect from & repair any punctures[3]


Moisture Control


NCC 2022 V1


All Building Classes


NCC 2022, F1D7 & Part 4.2.8 [2019 F1.10, 3.2.2.6]


May 2023



AS 2870:2011, 5.3.3.2 (a)

AS 2870:2011, 5.3.3.2 (a) (i)

AS 2870:2011, 5.3.3.2 (a) (ii)

AS 2870:2011, 5.3.3.4 (b)

AS 2870:2011, 5.3.3.4 (a)

AS 2870:2011, 5.3.3.4 (c)

AS 2870:2011, 5.3.3.3 (c)

AS 2870:2011, 5.3.3.4 (a)

AS 2870:2011, 5.3.3.4 (a)

Reinforcement


  • ≤ 800mm Bar Chair spacing[1]
  • Top & bottom Bars of equal size & specification[2]
  • Fix Ties to prevent movement[3]


Chair RULES


NCC 2022 V1


All Building Classes


NCC 2022, 4.2.11 [2019:3.2.3.2]



May 2023



NCC 2022 HP, 4.2.11 (7) (e)

NCC 2022 HP, 4.2.11 (7) (a)

NCC 2022 HP, 4.2.11 (7) (b)

NCC 2022 HP, 4.2.11 (7) (b)

Waffle Raft Reinforcement RULES


NCC 2022 V3


All Building Classes


NCC 2022 4.2 [2019 3.2]




May 2023



AS 2870:2011, 3.4.3

AS 2870:2011, 3.4.3

  • Construction of Footings & Slabs to comply with NCC Part 4.2 & AS 2870
  • Top & bottom Bars of the same size & specificationAS 2870:2011, 3.4.3
  • Waffle Raft Beams with
  • > 150mm Stem Width, to add Reinforcement according to Table below (Additional Reinforcement)AS 2870:2011, 3.4.3


NCC 2022 HP, 4.2.11 (7) (e)

NCC 2022 HP, 4.2.11 (7) (a)

AS 2870:2011, 3.4.3

Edge Rebate

Concrete Cover


  • ≥ 30mm over membrane[1]
  • ≥ 40mm unprotected ground[2]
  • ≥ 20mm internal surface[3]
  • ≥ 40mm external exposure[4]


Concrete COVER


NCC 2022 V3


All Building Classes


NCC 2022 4.2.11 [2019 3.2.3.2]


May 2023



AS 3600:2018, 4.10.3.2

AS 3600:2018, 4.3.1 (c)

  • Concrete must comply with the NCC
  • Cover for standard Formwork & compaction as per tableAS 3600:2018, 4.10.3.2
  • Add thickness where cast against ground
  • Embedded elements must be protected from corrosion or deteriorationAS 3600:2018, 4.3.1 (c)

NCC 2022 HP, 4.2.11 (5) (b)

NCC 2022 HP, 4.2.11 (5) (a)

NCC 2022 HP, 4.2.11 (5) (c)

NCC 2022 HP, 4.2.11 (5) (d)

Termite Management


  • Where Termite risk is identified
  • ≥ 75mm Wall exposure between ground level & Termite Sheet, to allow visual detection of Termites[1]


Durable Notice RULES


NCC 2022 V1


All Building Classes


NCC 2022, 3.4.3


May 2023



NCC 2022 HP, 3.4.3

NCC 2022 HP, 3.4.3

NCC 2022 HP, 3.4.3 (a)

NCC 2022 HP, 3.4.3 (b)

NCC 2022 HP, 3.4.3 (c)

NCC 2022 HP, 3.4.3 (d)

Termite RISK


NCC 2022 V1


All Building Classes


NCC 2022, H1D3 & 3.4.1 [2019 3.1.4.2]


May 2023



NCC 2022 HP, 3.4.1 (1) (a)

NCC 2022 HP, 3.4.1 (1) (b)

NCC 2022 HP, 3.4.1(2)

  • Termite Management System Required if
  • Location is identified at Risk of Attack, &NCC 2022 HP, 3.4.1 (1) (a)
  • Any Primary Building Element is susceptibleNCC 2022 HP, 3.4.1 (1) (b)
  • Primary Building Elements are
  • Any member designed to take Loads
  • Wall, Roof, Ceiling, Floor, Ramp or Stair Framing
  • Any bracing or other framing members
  • Materials not susceptible to attackNCC 2022 HP, 3.4.1(2)
  • Metals
  • Concrete
  • Masonry
  • Fibre-reinforced Concrete
  • Naturally resistant Timber
  • Preservative-treated Timber

Termite MANAGEMENT


NCC 2022 V3


All Building Classes


NCC 2022 H1D3 & 3.4.2 [2019 3.1.4.3]


May 2023



NCC 2022 HP, 3.4.2

AS 3660.1:2014, 4.4

  • Termite Management compliance to the NCC

Inspection ZoneNCC 2022 HP, 3.4.2AS 3660.1:2014, 4.4

  • ≥ 75mm exposed Concrete Face
  • Off form, smooth surface, free of Ripples or Honeycombing
  • Tiling, Render, Vapour Barrier, Flashings, Structures & the like, not allowed to bridge this Zone

AS 3660.1:2014, 4.4

  • Where Termite risk is identified
  • ≥ 75mm Wall exposure between ground level & Termite Sheet, to allow visual detection of TermitesAS 3660.1:2014, 4.4