Baths - Fitting Details Building Codes & Rules


- Baths and Spas Tools™ simplifies the National Construction Code (NCC) with interactive graphics, including deemed to comply & best practices.


M

M

Junctions


  • Batten off studs or Shelf junction[1]


Bath Junction TYPE


NCC 2022 V1


All Building Classes


NCC 2022 F2D2, & Part 10.2.20 [2019 F1.7]


May 2023



NCC 2022 HP, 10.2.20

AS 3740:2021, 4.13.2.2

  • Building elements in Wet Areas to be Waterproof or Water Resistant to NCC Part 10.2, & AS 3740
  • Bath & Spas waterproofed junctionsNCC 2022 HP, 10.2.20
  • Recessed in Wall
  • Sufficiently recess into wall to allow water to pass from the membraned wall lining, into the bath
  • ≥ 6mm Type 1 SealantAS 3740:2021, 4.13.2.2
  • Battened Junction
  • Battens to support the wall lining, allowing the bath rim to fit behind
  • Where notching of studs is not possible or bath adjacent to masonry or steel studwork
  • Shelf or Insert Bath
  • Waterstop ≥ 5mm above tile finished level
  • Do not allow bath to press down on Waterstop

NCC 2022 HP, 10.2.20

Membrane

Wall lining

Wall Lining


  • Flush drive screws or fibre cement nails
  • Sealant wipe over head


Wall Lining SELECTION


NCC 2022 V4


  • Flush drive screws or fibre cement nails
  • Sealant wipe over head

Bath & Spa

  • Support to prevent distortion & cracking
  • Maintain structural integrity when installing

Wall Finish

Adhesive

Stud Framing

Anti-fungal Sealant

≥ 6

Type 1 Sealant

Type 1 Sealant

Plumbing Penetrations


  • Seal between plumbing outlet & wall membrane[1][2]


Installation BEST PRACTICE


NCC 2022 V1


Plumbing PENETRATIONS


NCC 2022 V2


All Building Classes


NCC 2022 F2D2, S26C3 [2019 F1.7]

NCC 2022 H4D2, 10.2.23 [2019 3.8.1]


May 2023



NCC 2022 HP, 10.2.23 (b)

NCC 2022 HP, 10.2.23 (a)

  • Building elements in Wet Areas to be Waterproof or Water Resistant to NCC Specification 26, NCC Part 10.2, & AS 3740
  • Sealing
  • Fully waterproof gap between plumbing outlet & wall membraneNCC 2022 HP, 10.2.23 (b)
  • Proprietary flange adhered to wall
  • Sealant to wall & tap body junction
  • Seal must not impede servicing tap washers or ceramic disksNCC 2022 HP, 10.2.23 (a)

AS 3740:2021, 4.12.2

AS 3740:2021, 4.11.1 (b)