Cavity Slider Waterstop Building Codes & Rules


- Membrane Tools™ simplifies the National Construction Code (NCC) with interactive graphics, including deemed to comply & best practices.


Waterstop Angle

Split Jamb

Cavity Sliding Door

Finished Floor Level

Split Jamb

M

M

Substrate

M

Wall Lining

  • Adhere to cavity doorset

Sealant fillet

Waterstop

Angle

Sealant / Adhesive

Sealant bead

M

M

Top of Membrane

M

Finished Floor Level

NCC 2022 HP, 10.2.2 (1) (c)

AS 3740:2021, 4.11.2 (b)

≥ 40NCC 2022 HP, 10.2.2 (1) (c)AS 3740:2021, 4.11.2 (b)

Show finishes

AS 3740:2021, 4.9.1 (c) (ii)

≥ 25AS 3740:2021, 4.9.1 (c) (ii)

Structural Floor Level

AS 3740:2021, 4.9.1 (d)

≥ 150AS 3740:2021, 4.9.1 (d)

Membrane


  • Turn the Membrane down into the Leak Control Flange[1]
  • Compatible to suit Substrate & bedding / finishes[2]
  • Test & protect from damage[3]


Membrane AUDIT


NCC 2022 V2


All Building Classes


NCC 2022 F2D2, S26C3, 10.2.26 [2019 F1.7]


May 2023



AS 3740:2021, 4.5.4 (a)

AS 3740:2021, 4.5.4 (b)

AS 3740:2021, 4.5.4 (c)

AS 3740:2021, 4.5.2

  • Building elements in Wet Areas to be Waterproof or Water Resistant to NCC Specification 26, Part 10.2, & AS 3740
  • Curing & protectionAS 3740:2021, 4.5.4 (a)
  • Fully cured to manufacturers' recommendations
  • Protect from physical & chemical damage until covered by finishes
  • Flood testingAS 3740:2021, 4.5.4 (b)
  • If any leaks occur, these shall be repaired following the system design & retested
  • Electronic leak detectionAS 3740:2021, 4.5.4 (c)
  • If any discontinuities occur, these shall be repaired & retested only on the repaired areas
  • Seam probe testingAS 3740:2021, 4.5.2
  • If any seam failures occur, these shall be repaired & retested

Membrane Curing & Inspection RULES


NCC 2022 V2


All Building Classes


NCC 2022 F2D2, S26C3, 10.2.28 [2019 F1.7]



May 2023



AS 3740:2021, 4.5.2

AS 3740:2021, 4.5.3

  • Building elements in Wet Areas to be Waterproof or Water Resistant to NCC Specification 26, Part 10.2, & AS 3740
  • Fully cure prior to any testingAS 3740:2021, 4.5.2
  • Visual inspection conducted prior to application of overlay finishesAS 3740:2021, 4.5.3

AS 3740:2021, 4.3.1 (a)

AS 3740:2021, 3.2

AS 3740:2021, 4.17 (b)

Redirecting... (5)