Zero Threshold / Accessible Building Codes & Rules


- Zero Threshold / Accessible Tools™ simplifies the National Construction Code (NCC) with interactive graphics, including deemed to comply & best practices.


Fall

M

Adhesive

Underlay / Insulation

≥ 1:80

Fall

Substrate

Sealant

AS 3958.1:2007, A.2.3 (a)

Mortar Bedding

AS 4654.2:2012, 2.5.2

≥ 1:100AS 4654.2:2012, 2.5.2

M

M

Waterstop

returns

at Reveal

Removable Grate

Waterstop

  • Rebate, or
  • Waterstop angle

M

Internal Finished Floor

Fall

Sealant

M

M

Non-shrink Grout

Manufacturer's System Requirement

Drainage ChannelManufacturer's System Requirement

  • Proprietary system
  • Install to Manufacturer's Requirements
  • Secondary Drainage only

Fillet

Puddle Flange

Floor System

Foam Filler

Connect to Stormwater

Specify Outlet location

Accessible Compliant Door or Window Sill

Seal under Packing & over Screw Heads

AS 1428.1:2009, 7.2 (a)

≤ 3AS 1428.1:2009, 7.2 (a)

≥ 1:80

End Cap


  • Fully seal to sub-sill
  • ≥ 6mm gap to reveal with backing rod & sealant


End Cap WATERPROOFING


NCC 2022 V1


null
  • Fully seal to sub-sill
  • ≥ 6mm gap to reveal with backing rod & sealant

Tile

AS 1428.1:2009, 10.7.2 (a)

≤ 3AS 1428.1:2009, 10.7.2 (a)

Drains into Channel

Membrane

Outlet

Fillet

Sub-sill on Hob

Membrane Height


  • Height varies with wind class[1]


Height RULES


NCC 2022 V7


All Building Classes


NCC 2022 F1D5, H2D8, & HP10.2 [2019 F1.4, 3.8.1.2, 3.8.1.3]


May 2023



AS 4654.2:2012, 2.8.1

NCC 2022 Vol 1, F1D5

NCC 2022 Vol 2, H2D8

NCC 2022 HP, 10.2.1

  • Building elements in Wet Areas to be Waterproof or Water Resistant to the NCCAS 4654.2:2012, 2.8.1NCC 2022 Vol 1, F1D5NCC 2022 Vol 2, H2D8
  • Measured from top of finished external level to height of MembraneNCC 2022 HP, 10.2.1
  • FFL in the case of a finish on a Screed Bed, or
  • Base of Linear Drain at Zero Threshold Entry, or
  • Substrate Membrane where Pavers on Pedestals
  • Height sufficient to prevent wind-driven water entry

AS 4654.2:2012, 2.8.1.1

Brick Veneer



Brick Veneer BEST PRACTICE


NCC 2022 V1


  • Use termite-resistant structure
  • Such as Treated Timber or Steel
  • This eliminates the need for Slab Edge Exposure
  • Use Zero Threshold, including Strip Drain, for doorways provided that
  • 3mm lip water check is always applied
  • ≥ 20mm Set down at base of Wall
  • Adjust levels and establish the paving level below the set down base
  • Give careful attention & collaborate with the concreter or paver
  • Especially when transitioning from a strip drain to the paving areas

Termite Management


  • Zero Thresholds & other flush Entry points will breach a Termite Management System
  • Non-termite susceptible Primary Building Elements must be used[1]


Termite RISK


NCC 2022 V1


All Building Classes


NCC 2022, H1D3 & 3.4.1 [2019 3.1.4.2]


May 2023



NCC 2022 HP, 3.4.1 (1) (a)

NCC 2022 HP, 3.4.1 (1) (b)

NCC 2022 HP, 3.4.1(2)

  • Termite Management System Required if
  • Location is identified at Risk of Attack, &NCC 2022 HP, 3.4.1 (1) (a)
  • Any Primary Building Element is susceptibleNCC 2022 HP, 3.4.1 (1) (b)
  • Primary Building Elements are
  • Any member designed to take Loads
  • Wall, Roof, Ceiling, Floor, Ramp or Stair Framing
  • Any bracing or other framing members
  • Materials not susceptible to attackNCC 2022 HP, 3.4.1(2)
  • Metals
  • Concrete
  • Masonry
  • Fibre-reinforced Concrete
  • Naturally resistant Timber
  • Preservative-treated Timber

NCC 2022 HP, 3.4.1

  • Zero Thresholds & other flush Entry points will breach a Termite Management System
  • Non-termite susceptible Primary Building Elements must be usedNCC 2022 HP, 3.4.1

Concrete Screeds

Sub-sill with Set Down

Fixings


  • ≤ 600mm[1] CTS
  • Seal to prevent water ingress[2]


Fixing RULES


NCC 2022 V3


All Building Classes


NCC 2022 J5D5, H6D2, & HP13.4.4 [2019 J3.4, 3.12.0, 3.12.3.3]


May 2023



NCC 2022 HP, 13.4.4

NCC 2022 Vol 1, J5D5 (1)

NCC 2022 Vol 2, H6D2 (1)

AS 4654.2:2012, 2.8.3

Fixing BEST PRACTICE


NCC 2022 V1


AS 4654.2:2012, 2.8.3

Manufacturer's System Requirement

Substrate


  • Fall to drainage point preferred[1]
  • Smooth & clean prior to waterproofing[2]


Substrate PREPARATION


NCC 2022 V1


Substrate PREPARATION


NCC 2022 V6


All Building Classes


NCC 2022 F2D2, S26C3, & HP10.2.9 [2019 F1.7]


May 2023



AS 3740:2021, 4.4.1

NCC 2022 Vol 1, F2D2

NCC 2022 Vol 1, S26C3 (1)

NCC 2022 HP, 10.2.9

  • Building elements in Wet Areas to be Waterproof or Water Resistant to the NCCAS 3740:2021, 4.4.1NCC 2022 Vol 1, F2D2NCC 2022 Vol 1, S26C3 (1)
  • All surfaces to be prepared for Waterproofing System adhesionNCC 2022 HP, 10.2.9
  • Smooth, dust-free, clean & dry surface
  • Fill voids
  • Grind smooth any protrusions
  • Free of formwork deformity
  • Prime substrate to prohibit pin-holing during the membrane curing process
  • Moisture test & apply primer as per Manufacturer's Recommendations

AS 4654.2:2012, 2.5.2

AS 4654.2:2012, 2.5.3

Membrane


  • ≥ 1 : 100[1] fall to drainage
  • ≥ 1 : 60 recommended
  • System compatible & to suit application[2]


Membrane AUDIT


NCC 2022 V1


All building classes


AS 4654.2 2012, 2.16


14 Sep 2012 to Current



Membrane RULES


NCC 2022 V5


All Building Classes


NCC 2022 F1D5, H2D8, & HP10.2 [2019 F1.4, 3.8.1.2, 3.8.1.3]


May 2023



AS 4654.2:2012, 2.5.2

NCC 2022 Vol 1, F1D5

NCC 2022 Vol 2, H2D8

NCC 2022 HP, 10.2.1

AS 4654.2:2012, 2.3

AS 4654.2:2012, 2.5.3

AS 4654.2:2012, 2.7

AS 4654.2:2012, 2.6.2

Waterproof Membrane BEST PRACTICE


NCC 2022 V1


AS 4654.2:2012, 2.5.1

AS 4654.2:2012, 2.5.2

Floor Finish


  • Fall to drainage
  • ≥ 1 : 100[1]
  • ≥ 1 : 80 recommended
  • ≥ P3 or R10 Slip Rating[2]


Surface FINISHES


NCC 2022 V4


All Building Classes


NCC 2022 F1D5, H2D8, & HP10.2 [2019 F1.4, 3.8.1.2, 3.8.1.3]


May 2023



AS 4654.2:2012, 2.15.2

AS 4654.2:2012, 2.15.2

NCC 2022 Vol 1, F1D5

NCC 2022 Vol 2, H2D8

NCC 2022 HP, 10.2.1

AS 4654.2:2012, 2.15.1

AS 4654.2:2012, 2.15.3

HB 198:2014, 5.1

AS 4654.2:2012, 2.5.2