Zero Threshold / Accessible Building Codes & Rules


- Zero Threshold / Accessible Tools™ simplifies the National Construction Code (NCC) with interactive graphics, including deemed to comply & best practices.


Fall

M

Adhesive

Underlay / Insulation

≥ 1:80

Fall

Substrate

Sealant

AS 3958.1:2007, A.2.3 (a)

Mortar Bedding

AS 4654.2:2012, 2.5.2

≥ 1:100AS 4654.2:2012, 2.5.2

M

M

Waterstop

returns

at Reveal

Removable Grate

Waterstop

  • Rebate, or
  • Waterstop angle

M

Internal Finished Floor

Fall

Sealant

M

M

Non-shrink Grout

Manufacturer's System Requirement

Drainage ChannelManufacturer's System Requirement

  • Proprietary system
  • Install to Manufacturer's Requirements
  • Secondary Drainage only

Fillet

Puddle Flange

Floor System

Foam Filler

Connect to Stormwater

Specify Outlet location

Accessible Compliant Door or Window Sill

Seal under Packing & over Screw Heads

AS 1428.1:2009, 7.2 (a)

≤ 3AS 1428.1:2009, 7.2 (a)

≥ 1:80

End Cap


  • Fully seal to sub-sill
  • ≥ 6mm gap to reveal with backing rod & sealant


End Cap WATERPROOFING


NCC 2022 V1


null
  • Fully seal to sub-sill
  • ≥ 6mm gap to reveal with backing rod & sealant

Tile

AS 1428.1:2009, 10.7.2 (a)

≤ 3AS 1428.1:2009, 10.7.2 (a)

Drains into Channel

Membrane

Outlet

Fillet

Brick Veneer



Brick Veneer BEST PRACTICE


NCC 2022 V1


  • Use termite-resistant structure
  • Such as Treated Timber or Steel
  • This eliminates the need for Slab Edge Exposure
  • Use Zero Threshold, including Strip Drain, for doorways provided that
  • 3mm lip water check is always applied
  • ≥ 20mm Set down at base of Wall
  • Adjust levels and establish the paving level below the set down base
  • Give careful attention & collaborate with the concreter or paver
  • Especially when transitioning from a strip drain to the paving areas

Membrane Height


  • Height varies with wind class[1]


Height RULES


NCC 2022 V7


All Building Classes


NCC 2022 F1D5, H2D8, & HP10.2 [2019 F1.4, 3.8.1.2, 3.8.1.3]


May 2023



AS 4654.2:2012, 2.8.1

NCC 2022 Vol 1, F1D5

NCC 2022 Vol 2, H2D8

NCC 2022 HP, 10.2.1

  • Building elements in Wet Areas to be Waterproof or Water Resistant to the NCCAS 4654.2:2012, 2.8.1NCC 2022 Vol 1, F1D5NCC 2022 Vol 2, H2D8
  • Measured from top of finished external level to height of MembraneNCC 2022 HP, 10.2.1
  • FFL in the case of a finish on a Screed Bed, or
  • Base of Linear Drain at Zero Threshold Entry, or
  • Substrate Membrane where Pavers on Pedestals
  • Height sufficient to prevent wind-driven water entry

AS 4654.2:2012, 2.8.1.1

Sub-sill on Hob

Concrete Screeds

Termite Management


  • Zero Thresholds & other flush Entry points will breach a Termite Management System
  • Non-termite susceptible Primary Building Elements must be used[1]


Termite RISK


NCC 2022 V1


All Building Classes


NCC 2022, H1D3 & 3.4.1 [2019 3.1.4.2]


May 2023



NCC 2022 HP, 3.4.1 (1) (a)

NCC 2022 HP, 3.4.1 (1) (b)

NCC 2022 HP, 3.4.1(2)

  • Termite Management System Required if
  • Location is identified at Risk of Attack, &NCC 2022 HP, 3.4.1 (1) (a)
  • Any Primary Building Element is susceptibleNCC 2022 HP, 3.4.1 (1) (b)
  • Primary Building Elements are
  • Any member designed to take Loads
  • Wall, Roof, Ceiling, Floor, Ramp or Stair Framing
  • Any bracing or other framing members
  • Materials not susceptible to attackNCC 2022 HP, 3.4.1(2)
  • Metals
  • Concrete
  • Masonry
  • Fibre-reinforced Concrete
  • Naturally resistant Timber
  • Preservative-treated Timber

NCC 2022 HP, 3.4.1

  • Zero Thresholds & other flush Entry points will breach a Termite Management System
  • Non-termite susceptible Primary Building Elements must be usedNCC 2022 HP, 3.4.1

Sub-sill with Set Down

Fixings


  • ≤ 600mm[1] CTS
  • Seal to prevent water ingress[2]


Fixing BEST PRACTICE


NCC 2022 V1


Fixing RULES


NCC 2022 V3


All Building Classes


NCC 2022 J5D5, H6D2, & HP13.4.4 [2019 J3.4, 3.12.0, 3.12.3.3]


May 2023



NCC 2022 HP, 13.4.4

NCC 2022 Vol 1, J5D5 (1)

NCC 2022 Vol 2, H6D2 (1)

AS 4654.2:2012, 2.8.3

AS 4654.2:2012, 2.8.3

Manufacturer's System Requirement

Substrate


  • Fall to drainage point preferred[1]
  • Smooth & clean prior to waterproofing[2]


Substrate PREPARATION


NCC 2022 V1


Substrate PREPARATION


NCC 2022 V6


All Building Classes


NCC 2022 F2D2, S26C3, & HP10.2.9 [2019 F1.7]


May 2023



AS 3740:2021, 4.4.1

NCC 2022 Vol 1, F2D2

NCC 2022 Vol 1, S26C3 (1)

NCC 2022 HP, 10.2.9

  • Building elements in Wet Areas to be Waterproof or Water Resistant to the NCCAS 3740:2021, 4.4.1NCC 2022 Vol 1, F2D2NCC 2022 Vol 1, S26C3 (1)
  • All surfaces to be prepared for Waterproofing System adhesionNCC 2022 HP, 10.2.9
  • Smooth, dust-free, clean & dry surface
  • Fill voids
  • Grind smooth any protrusions
  • Free of formwork deformity
  • Prime substrate to prohibit pin-holing during the membrane curing process
  • Moisture test & apply primer as per Manufacturer's Recommendations

AS 4654.2:2012, 2.5.2

AS 4654.2:2012, 2.5.3

Membrane


  • ≥ 1 : 100[1] fall to drainage
  • ≥ 1 : 60 recommended
  • System compatible & to suit application[2]


Membrane AUDIT


NCC 2022 V1


All building classes


AS 4654.2 2012, 2.16


14 Sep 2012 to Current



Waterproof Membrane BEST PRACTICE


NCC 2022 V1


Membrane RULES


NCC 2022 V5


All Building Classes


NCC 2022 F1D5, H2D8, & HP10.2 [2019 F1.4, 3.8.1.2, 3.8.1.3]


May 2023



AS 4654.2:2012, 2.5.2

NCC 2022 Vol 1, F1D5

NCC 2022 Vol 2, H2D8

NCC 2022 HP, 10.2.1

AS 4654.2:2012, 2.3

AS 4654.2:2012, 2.5.3

AS 4654.2:2012, 2.7

AS 4654.2:2012, 2.6.2

AS 4654.2:2012, 2.5.1

AS 4654.2:2012, 2.5.2

Floor Finish


  • Fall to drainage
  • ≥ 1 : 100[1]
  • ≥ 1 : 80 recommended
  • ≥ P3 or R10 Slip Rating[2]


Surface FINISHES


NCC 2022 V4


All Building Classes


NCC 2022 F1D5, H2D8, & HP10.2 [2019 F1.4, 3.8.1.2, 3.8.1.3]


May 2023



AS 4654.2:2012, 2.15.2

AS 4654.2:2012, 2.15.2

NCC 2022 Vol 1, F1D5

NCC 2022 Vol 2, H2D8

NCC 2022 HP, 10.2.1

AS 4654.2:2012, 2.15.1

AS 4654.2:2012, 2.15.3

HB 198:2014, 5.1

AS 4654.2:2012, 2.5.2

Redirecting... (5)