External Waterproofing (Benchmark) Building Codes & Rules


- External Waterproofing Benchmark: Tools™ simplifies the National Construction Code (NCC) with interactive graphics, including deemed to comply & best practices.


Fall

Fall

Fall

Sealant Joint

Fall

Waterproofing materials to AS 4654.1

AS 4654.2:2012, 2.5.2

≥ 1 : 100AS 4654.2:2012, 2.5.2

AS 4654.2:2012, 2.5.2

≥ 1 : 100AS 4654.2:2012, 2.5.2

AS 4654.2:2012, 2.5.2

≥ 1 : 100AS 4654.2:2012, 2.5.2

AS 4654.2:2012, 2.5.2

≥ 1 : 100AS 4654.2:2012, 2.5.2

Film Thickness Test

Threshold

Post Support

Screed

Floor Finish


  • ≥ 1 : 100 Fall to drainage[1]
  • ≥ P3 or R10 Slip Rating[2]
  • ≤ 4.5m CTS Movement Joints[3]


Slip RATING


NCC 2022 V2


All Building Classes


NCC 2022 D1P2


May 2023



Surface FINISHES


NCC 2022 V3


All Building Classes


NCC 2022 F2D2, S26C3, HP10.2.11 to 13 [2019 F1.7]


May 2023



AS 4654.2:2012, 2.15.2

AS 4654.2:2012, 2.15.2

NCC 2022 Vol 1, F2D2

  • Building elements in Wet Areas to be Waterproof or Water Resistant to the NCCAS 4654.2:2012, 2.15.2
  • Overlaying system not to harm & be suitable with the membrane
  • Membrane bonded to topping or beddingAS 4654.2:2012, 2.15.2
  • ≥ 10mm movement joint width at ≤ 4.5m CTS
  • Structural toppingNCC 2022 Vol 1, F2D2
  • ≥ 50mm thick with light mesh reinforcement
  • Install double slip sheet on top of membrane
  • Align movement joints in finishes over all building construction, control or movement joints

AS 4654.2:2012, 2.15.2

AS 4654.2:2012, 2.5.2

HB 198:2014, 5.1

Movement Joint

Flashing

Overflow

End Cap


  • Fully seal to sub-sill
  • ≥ 6mm gap to reveal with backing rod & sealant


End Cap WATERPROOFING


NCC 2022 V1


null
  • Fully seal to sub-sill
  • ≥ 6mm gap to reveal with backing rod & sealant

Planter Box

Site Tools

Parapet

Floor Waste

Fillets


  • 40 x 40mm[1] Sheet Membrane
  • 15 x 15mm[2] Liquid Membrane


Fillet RULES


NCC 2022 V3


All Building Classes


NCC 2022 F2D2, S26C6, & 10.2.6 [2019 F1.7, 3.8.1.3]


May 2023



AS 4654.2:2012, 2.7

  • Building elements in Wet Areas to be Waterproof or Water-resistant to NCC Specification 26, Part 10.2 & AS 4654.2
  • Membrane transitions from horizontal to vertical, or vertical to vertical planes, require the implementation of a Fillet, Cove, or Bond BreakerAS 4654.2:2012, 2.7
  • 40x40mm Fillet or cove for Sheet Membrane
  • 15x15mm Fillet or Bond Breaker for Liquid Membrane

Membrane RULES


NCC 2022 V3


All Building Classes


NCC 2022 F2D2, S26C3, HP10.2.6 [2019 Table F1.7, 3.8.1.3]


May 2023



AS 4654.2:2012, 2.5.2

  • Building elements in Wet Areas to be Waterproof or Water Resistant to the NCC
  • ≥ 1 : 100 fall in Membrane to Drainage OutletAS 4654.2:2012, 2.5.2
  • Structural Substrate or Screed to form the required Falls
  • Design & installation in accordance with AS 4654.1
  • Membrane movement Class I, II, or III
  • To suit intended service conditions
  • Substrate to be smooth, clean, dry & dust-free
  • Fillets & Bond Breakers installed on all corners
  • Lay & allow to cure as per Manufacturer's Recommendations

AS 4654.2:2012, 2.7

AS 4654.2:2012, 2.7

Fixings


  • ≤ 600mm CTS[1]
  • Seal to prevent water ingress[2]


Fixing BEST PRACTICE


NCC 2022 V1


Fixing RULES


NCC 2022 V1


All Building Classes


NCC 2022 J5D5, H6V3, & 13.4.4

[2019 J3.4, V2.6.2.3, 3.12.3.3]


May 2023



AS 4654.2:2012, 2.8.3

NCC 2022 HP, 13.4.4

NCC 2022 Vol 1, J5D5 (1)

Manufacturer's System Requirement

AS 4654.2:2012, 2.8.3

Roof Deck

Balustrade

Film Thickness Test Points

Waterproofing Verification



Falls Verification & Record


NCC 2022 V1


null

Moisture Content Verification & Record


NCC 2022 V1


null

Penetrations

Redirecting... (5)