Discontinuous Building Codes & Rules


- Discontinuous Tools™ simplifies the National Construction Code (NCC) with interactive graphics, including deemed to comply & best practices.


AS 4654.2:2012, 2.5.2

≥ 1:100AS 4654.2:2012, 2.5.2

Fall

Fall

M

Fall

M

M

M

Waterproofing Termination

Strip or Bar - RCC Requirement

Top Hat

Brackets to allow

for Movement

Packer

M

Structural Substrate

Drainage Tray

Drainage Tray

  • Continuous under Joint
  • Connect to Stormwater Drainage
  • Slotted or oversize Fixing Holes for movement

M

Finished Level

≥ 20

≥ 1:50

≥ 20

≥ 1:50

Waterproofing Termination

Strip or Bar - Taylor Requirement

Waterproofing Termination

Strip or Bar

AS 4654.2:2012, 2.5.2

≥ 1:100AS 4654.2:2012, 2.5.2

≥ 1:50

Drainage Tray

  • Continuous under Joint
  • Connect to Stormwater Drainage
  • Slotted or oversize Fixing Holes for movement

Drainage Tray

  • Continuous under Joint
  • Connect to Stormwater Drainage
  • Slotted or oversize Fixing Holes for movement

Metal Capping

Fillet

≥ 20

Flexible

Membrane

Expansion Loop

Overfill Sealant Joint

Fillet

Backing Rod

Membrane

Fillet


  • 40 x 40mm[1] Sheet Membrane Fillet or Cove
  • 15 x 15mm[2] Liquid Membrane Fillet or Bond Breaker


Fillet RULES


NCC 2022 V4


All Building Classes


NCC 2022 F1D5, H2D8, & HP10.2 [2019 F1.4, 3.8.1.2, 3.8.1.3]


May 2023



AS 4654.2:2012, 2.7

NCC 2022 Vol 1, F1D5

NCC 2022 Vol 2, H2D8

NCC 2022 HP, 10.2.1

  • Building elements in Wet Areas to be Waterproof or Water-resistant to the NCCAS 4654.2:2012, 2.7NCC 2022 Vol 1, F1D5NCC 2022 Vol 2, H2D8
  • Membrane transitions from horizontal to vertical, or vertical to vertical planes, require the implementation of a Fillet, Cove, or Bond BreakerNCC 2022 HP, 10.2.1
  • 40 x 40mm Fillet or cove for Sheet Membrane
  • 15 x 15mm Fillet or Bond Breaker for Liquid Membrane

AS 4654.2:2012, 2.7

AS 4654.2:2012, 2.7

Membrane


  • ≥ 1 : 100[1] fall to drainage
  • System compatible & to suit application[2]


Membrane AUDIT


NCC 2022 V1


All building classes


AS 4654.2 2012, 2.16


14 Sep 2012 to Current



Membrane RULES


NCC 2022 V5


All Building Classes


NCC 2022 F1D5, H2D8, & HP10.2 [2019 F1.4, 3.8.1.2, 3.8.1.3]


May 2023



AS 4654.2:2012, 2.5.2

NCC 2022 Vol 1, F1D5

NCC 2022 Vol 2, H2D8

NCC 2022 HP, 10.2.1

AS 4654.2:2012, 2.3

AS 4654.2:2012, 2.5.3

AS 4654.2:2012, 2.7

AS 4654.2:2012, 2.6.2

Waterproof Membrane BEST PRACTICE


NCC 2022 V1


AS 4654.2:2012, 2.5.2

AS 4654.2:2012, 2.5.1