Discontinuous Building Codes & Rules


- Discontinuous Tools™ simplifies the National Construction Code (NCC) with interactive graphics, including deemed to comply & best practices.


AS 4654.2:2012, 2.5.2

≥ 1:100AS 4654.2:2012, 2.5.2

Fall

Fall

M

Fall

M

M

M

Waterproofing Termination

Strip or Bar - RCC Requirement

Top Hat

Brackets to allow

for Movement

Packer

M

Structural Substrate

Drainage Tray

Drainage Tray

  • Continuous under Joint
  • Connect to Stormwater Drainage
  • Slotted or oversize Fixing Holes for movement

M

Finished Level

≥ 20

≥ 1:50

≥ 20

Membrane


  • ≥ 1 : 100[1] fall to drainage
  • System compatible & to suit application[2]


Membrane AUDIT


NCC 2022 V1


All building classes


AS 4654.2 2012, 2.16


14 Sep 2012 to Current



Membrane RULES


NCC 2022 V3


All Building Classes


NCC 2022 F2D2, S26C3, HP10.2.6 [2019 Table F1.7, 3.8.1.3]


May 2023



AS 4654.2:2012, 2.5.2

  • Building elements in Wet Areas to be Waterproof or Water Resistant to the NCC
  • ≥ 1 : 100 fall in Membrane to Drainage OutletAS 4654.2:2012, 2.5.2
  • Structural Substrate or Screed to form the required Falls
  • Design & installation in accordance with AS 4654.1
  • Membrane movement Class I, II, or III
  • To suit intended service conditions
  • Substrate to be smooth, clean, dry & dust-free
  • Fillets & Bond Breakers installed on all corners
  • Lay & allow to cure as per Manufacturer's Recommendations

Waterproof Membrane BEST PRACTICE


NCC 2022 V1


AS 4654.2:2012, 2.5.2

AS 4654.2:2012, 2.5.1

≥ 1:50

Waterproofing Termination

Strip or Bar - Taylor Requirement

Waterproofing Termination

Strip or Bar

AS 4654.2:2012, 2.5.2

≥ 1:100AS 4654.2:2012, 2.5.2

≥ 1:50

Drainage Tray

  • Continuous under Joint
  • Connect to Stormwater Drainage
  • Slotted or oversize Fixing Holes for movement

Drainage Tray

  • Continuous under Joint
  • Connect to Stormwater Drainage
  • Slotted or oversize Fixing Holes for movement

Metal Capping

Fillet

≥ 20

Flexible

Membrane

Expansion Loop

Overfill Sealant Joint

Fillet

Backing Rod

Membrane

Fillet


  • 40 x 40mm[1] Sheet Membrane Fillet or Cove
  • 15 x 15mm[2] Liquid Membrane Fillet or Bond Breaker


Fillet RULES


NCC 2022 V3


All Building Classes


NCC 2022 F2D2, S26C6, & 10.2.6 [2019 F1.7, 3.8.1.3]


May 2023



AS 4654.2:2012, 2.7

  • Building elements in Wet Areas to be Waterproof or Water-resistant to NCC Specification 26, Part 10.2 & AS 4654.2
  • Membrane transitions from horizontal to vertical, or vertical to vertical planes, require the implementation of a Fillet, Cove, or Bond BreakerAS 4654.2:2012, 2.7
  • 40x40mm Fillet or cove for Sheet Membrane
  • 15x15mm Fillet or Bond Breaker for Liquid Membrane

AS 4654.2:2012, 2.7

AS 4654.2:2012, 2.7

Redirecting... (5)
Please wait while we redirect you to the correct page.