Base of Parapet Building Codes & Rules


- Base of Parapet Tools™ simplifies the National Construction Code (NCC) with interactive graphics, including deemed to comply & best practices.


Tools™ Best Practice

≥ 1 : 80Tools™ Best Practice

AS 4654.2:2012, 2.5.2

≥ 1 : 100AS 4654.2:2012, 2.5.2

AS 4654.2:2012, 2.11

Membrane

AS 4654.2:2012, 1.5

AS 4654.2:2012, 2.11

Membrane Protection

Tools™ Best Practice

Tools™ Best Practice

Fall to Drain

M

M

Finished Level

M

M

Fall

AS 4654.2:2012, 2.11

LocationAS 4654.2:2012, 2.11

  • Above finished level & in a visible location
  • Direct water away from building
  • Visible so blockages can be easily detected

Preformed Outlet

with Face Flange

Hob Upturn

or Parapet

Floor System

Drip Groove

Membrane

Substrate

Preparation

Fillet

Tools™ Best Practice

≥ 50Tools™ Best Practice

Overflow through Parapet

Membrane Height


  • Height varies with wind class[1][2]


Membrane Height RULES


NCC 2022 V1


All Building Classes


NCC 2022 F1D5 [2019 Table F1.4]


May 2023



NCC 2022 Vol 1, F1D5

AS 4654.2:2012, 2.8.1.1

AS 4654.2:2012, A

  • A roof, balcony, podium or similar horizontal surface part of a building must be provided with a waterproofing membraneNCC 2022 Vol 1, F1D5
  • To AS 4654.1 & AS 4654.2
  • Unless is a deck or perforated or directly above ground
  • Measured from top of surface finish to height of membraneAS 4654.2:2012, 2.8.1.1
  • Height sufficient to prevent wind-driven water entry
  • Varies depending on wind class & level of protection
  • Termination heights to AS 4654.2 2012, Table A1 are minimum & informative onlyAS 4654.2:2012, A
  • Must be specified based on individual project wind classification

AS 4654.2:2012, 2.8.1.1

AS 4654.2:2012, A