Shower Screen Hob Building Codes & Rules


- Hob Tools™ simplifies the National Construction Code (NCC) with interactive graphics, including deemed to comply & best practices.


Door Near Shower

Shower Screen

M

Adhesive

Fall to FW

Fall to FW

NCC 2022 Vol 1, F2D4 (2)

NCC 2022 HP, 10.2.12 (a)

1 : 80 to 1 : 50NCC 2022 Vol 1, F2D4 (2)NCC 2022 HP, 10.2.12 (a)

Hob

  • Concrete or masonry
  • Timber not allowed

Sealant

Screed

Floor Tile

NCC 2022 Vol 1, F2D4 (2)

NCC 2022 HP, 10.2.12 (a)

1 : 80 to 1 : 50NCC 2022 Vol 1, F2D4 (2)NCC 2022 HP, 10.2.12 (a)

Junction


  • Bond breaker, tape, or sealant[1]
  • Compatible with the membrane class[2]


Junction RULES


NCC 2022 V4


All Building Classes


NCC 2022 F2D2, S26C3, & Part 10.2.24 [2019 F1.7, 3.8.1]


May 2023



AS 3740:2021, 4.10

AS 3740:2021, 4.13.2.2

  • NCC 2022 F2D2, S26C3, & Part 10.2.24 [2019 F1.7, 3.8.1]
  • Building elements in Wet Areas to be Waterproof or Water Resistant to NCC Specification 26, NCC Part 10.2, & AS 3740
  • Backing rod, tape, or sealant should be installed when the membrane is bonded to the substrate
  • Type depending on membrane flexibility classAS 3740:2021, 4.10

Class I Membrane (low extensibility)

  • Resin systems, or water-based epoxies membranes
  • ≥ 6mm ØAS 3740:2021, 4.13.2.2 backing rod should be installed to allow the membranes to flex instead of stretch, with a continuous tape between backing rod and membrane to keep it in place

Class II Membrane (medium extensibility)

  • Acrylic membranes, bitumen-based emulsions or mastics membranes
  • Tape to allow the membrane to stretch

Class III Membrane (high extensibility)

  • Polyurethane, PVC, rubber, or EPDM membrane
  • Fillet or sealant to allow even thickness to the membrane

AS 3740:2021, 4.10

AS 3740:2021, 4.10

Shower Screen


  • Installed to direct water into the Shower[1]


Shower Screen RULES


NCC 2022 V2


All Building Class


NCC 2022 F2D2, S26C3, & Part 10.2.16 to 13 [2019 F1.7]


May 2023 May 2023



NCC 2022 Vol 1, S26C1 (a)

NCC 2022 HP, 10.2.1

AS 3740:2021, 4.15.1

AS 3740:2021, 4.15.1

Slip Rating



Slip RATING


NCC 2022 V1


All Building Classes


NCC 2022 D1P2


May 2023



Concrete Screeds

Finishing Tiles


  • Conceal unfinished or unglazed Tile Edges


Tile FINISHING


NCC 2022 V1


  • Conceal unfinished or unglazed Tile Edges

Sealant

Sealant

Fillet

Screed

Sealant

Substrate

Shower Side

Membrane

M

Sealant

M

M

M

Fall into Shower