Shower Setdown Building Codes & Rules


- Shower Setdown Tools™ simplifies the National Construction Code (NCC) with interactive graphics, including deemed to comply & best practices.


Fall to FW

AS 3740:2021, 4.2

NCC 2022 HP, 10.2.21

Sealer MembraneAS 3740:2021, 4.2NCC 2022 HP, 10.2.21

M

M

Anti-fungal Sealant

Fall to FW

M

Bathroom Floor

M

Adhesive

Floor System

NCC 2022 Vol 1, F2D4 (2)

NCC 2022 HP, 10.2.12 (a)

1 : 80 to 1 : 50NCC 2022 Vol 1, F2D4 (2)NCC 2022 HP, 10.2.12 (a)

Sealant

Optional Cover Angle

Cover Angle - RCC Requirement

Falls

AS 3740:2021, 4.2

NCC 2022 HP, 10.2.21

Sealer MembraneAS 3740:2021, 4.2NCC 2022 HP, 10.2.21

AS 3740:2021, 4.11.1

Sealant BeadAS 3740:2021, 4.11.1

Screed

Shower Floor

Adhesive

Fall to FW

Screed

AS 3740:2021, 2.3.1

AS 3740:2021, 2.3.2

1 : 100AS 3740:2021, 2.3.1 to 1: 80AS 3740:2021, 2.3.2

Set-down to shower area if required to maintain screed thickeness

NCC 2022 Vol 1, F2D4 (2)

NCC 2022 HP, 10.2.12 (a)

1 : 80 to 1 : 50NCC 2022 Vol 1, F2D4 (2)NCC 2022 HP, 10.2.12 (a)

AS 3740:2021, 2.3.1

AS 3740:2021, 2.3.2

1 : 100AS 3740:2021, 2.3.1 to 1: 80AS 3740:2021, 2.3.2

M

AS 3740:2021, 4.11.1

Sealant FilletAS 3740:2021, 4.11.1

Waterstop Angle

Unenclosed Shower

Internal Waterproofing Overview

Framed Shower Screen

Concrete Screeds

Shower Screen


  • Door to shed water into the shower


Preventing Water Damage


NCC 2022 V1


  • Door to shed water into the shower

Floor Tiles


  • P3 or R10 Slip Rating[1]
  • Falls to FW & transverse cuts to minimise ponding


Tile TOLERANCE


NCC 2022 V6


All Building Classes


NCC 2022 F2D2, S26C3 [2019 F1.7]

NCC 2022 HP10.2.12


May 2023



NCC 2022 Vol 1, F2D4 (2)

AS 3740:2021, 2.3.1

AS 3740:2021, 2.3.5

NSW 2017 Guide to Standards & Tolerances, 12.6

AS 3958.1:2007, 5.4.6 (c)

AS 3958.1:2007, 5.4.6 (a)

NCC 2022 HP, 10.2.12

NCC 2022 Vol 1, S26C1 (a)

NCC 2022 HP, 10.2.1

Slip RATING


NCC 2022 V2


All Building Classes


NCC 2022 D1P2


May 2023



NCC 2022 Vol 1, D1P2

NCC 2022 Vol 1, D3D15

HB 198:2014, 4.3.2 (Table 3A)

HB 198:2014, 5.2 (Table 3B)

HB 198:2014, 5.1

  • P3 or R10 Slip RatingHB 198:2014, 5.1
  • Falls to FW & transverse cuts to minimise ponding

Membrane Above Screed

Screed


  • Bonded 15mm to 40mm thk[1]
  • Unbonded ≥ 40mm thk[2]


Screed RULES


NCC 2022 V2


All Building Classes


NCC 2022 F2D2 & S26C3


May 2023



AS 3958.1:2007, A.2.3 (a)

AS 3958.1:2007, A.2.3 (b)

AS 3958.1:2007, 3.3.1.1 (b) (i)

AS 3958.1:2007, 3.3.2.2 (b) (i)

NCC 2022 Vol 1, S26C3 (1)

NCC 2022 Vol 1, F2D2

AS 3958.1:2007, A.2.3 (a)

AS 3958.1:2007, A.2.3 (b)

Waterstop Angle


  • Adhere & / or mechanically fix to substrate[1][2]
  • Sealant beads & fillets to protect membrane[3]


Showers


NCC 2022 V1


  • Separate from main area to AS 3740 by either
  • Hob, or
  • ≥ 15mm Setdown, or
  • ≥ 5mm Upstand Angle under Framed Screen
  • ≥ 1 : 80 fall required, Transverse cut large format Tiles

Waterstop RULES


NCC 2022 V3


All Building Classes


NCC 2022 F2D2, S26C3, & Part 10.2.11 to 13 [2019 F1.7]


May 2023



AS 3740:2021, 3.3.1 (a)

AS 3740:2021, 3.3.3 (a) (iv)

AS 3740:2021, 4.9

AS 3740:2021, 3.3.3 (b) (ii)

AS 3740:2021, 3.3.1 (c)

NCC 2022 HP, 10.2.1

NCC 2022 Vol 1, S26C1 (a)

Water Stop INSTALLATION


NCC 2022 V1


Showers


NCC 2022 V1


AS 3740:2021, 4.6.1

AS 3740:2021, 4.8.1

AS 3740:2021, A.5.3

Membrane


  • Turn the Membrane down into the Leak Control Flange[1]
  • Compatible to suit Substrate & bedding / finishes[2]
  • Test & protect from damage[3]


Membrane AUDIT


NCC 2022 V2


All Building Classes


NCC 2022 F2D2, S26C3, 10.2.26 [2019 F1.7]


May 2023



AS 3740:2021, 4.5.4 (a)

AS 3740:2021, 4.5.4 (b)

AS 3740:2021, 4.5.4 (c)

AS 3740:2021, 4.5.2

  • Building elements in Wet Areas to be Waterproof or Water Resistant to NCC Specification 26, Part 10.2, & AS 3740
  • Curing & protectionAS 3740:2021, 4.5.4 (a)
  • Fully cured to manufacturers' recommendations
  • Protect from physical & chemical damage until covered by finishes
  • Flood testingAS 3740:2021, 4.5.4 (b)
  • If any leaks occur, these shall be repaired following the system design & retested
  • Electronic leak detectionAS 3740:2021, 4.5.4 (c)
  • If any discontinuities occur, these shall be repaired & retested only on the repaired areas
  • Seam probe testingAS 3740:2021, 4.5.2
  • If any seam failures occur, these shall be repaired & retested

Membrane Curing & Inspection RULES


NCC 2022 V2


All Building Classes


NCC 2022 F2D2, S26C3, 10.2.28 [2019 F1.7]



May 2023



AS 3740:2021, 4.5.2

AS 3740:2021, 4.5.3

  • Building elements in Wet Areas to be Waterproof or Water Resistant to NCC Specification 26, Part 10.2, & AS 3740
  • Fully cure prior to any testingAS 3740:2021, 4.5.2
  • Visual inspection conducted prior to application of overlay finishesAS 3740:2021, 4.5.3

AS 3740:2021, 4.3.1 (a)

AS 3740:2021, 3.2

AS 3740:2021, 4.17 (b)

Finishes


  • Avoid stone & other absorbent materials
  • Isolate joinery from wet surfaces


Preventing Water Damage


NCC 2022 V1


  • Avoid stone & other absorbent materials
  • Isolate joinery from wet surfaces

Door Near Shower

AS 3740:2021, 4.2

NCC 2022 HP, 10.2.21

AS 3740:2021, 4.2

NCC 2022 HP, 10.2.21

AS 3740:2021, 4.11.1

Sealant /

AdhesiveAS 3740:2021, 4.11.1

Screed


  • Bonded 15mm to 40mm thk[1]
  • Unbonded ≥ 40mm thk[2]


Screed RULES


NCC 2022 V2


All Building Classes


NCC 2022 F2D2 & S26C3


May 2023



AS 3958.1:2007, A.2.3 (a)

AS 3958.1:2007, A.2.3 (b)

AS 3958.1:2007, 3.3.1.1 (b) (i)

AS 3958.1:2007, 3.3.2.2 (b) (i)

NCC 2022 Vol 1, S26C3 (1)

NCC 2022 Vol 1, F2D2

AS 3958.1:2007, A.2.3 (a)

AS 3958.1:2007, A.2.3 (b)

Membrane Substrate


  • ≥ 1 : 100 fall required towards the Floor Waste[1]
  • ≥ 1 : 80 fall required to entire room where Shower unscreened[2]
  • Form falls in Structural Floor or Screed[3]
  • Smooth, clean, dry & dust free surface[4]


Substrate PREPARATION


NCC 2022 V4


All Building Classes


NCC 2022 F2D2, S26C3, & HP10.2.9 [2019 F1.7]


May 2023



AS 3740:2021, 4.4.1

  • Building elements in Wet Areas to be Waterproof or Water Resistant to the NCC
  • All surfaces to be prepared for Waterproofing System adhesionAS 3740:2021, 4.4.1
  • Smooth, dust-free, clean & dry surface
  • Fill voids
  • Grind smooth any protrusions
  • Free of formwork deformity
  • Prime substrate to prohibit pin-holing during the membrane curing process
  • Moisture test & apply primer as per Manufacturer's Recommendations

Substrate PREPARATION


NCC 2022 V1


AS 3740:2021, 2.3

AS 3740:2021, 4.4.1

AS 3740:2021, 2.3.1

AS 3740:2021, 2.3.5

Shower Stepdown


  • ≥ 15mm Step-down[1]
  • Compliance option Class 1 & 10[2]
  • ≥ 25mm to NCC HP 2022[3]


Compliance Pathways


NCC 2022 V2


Class 1 & 10


NCC 2022 Vol 2, H4D2 & H4D3


May 2023



NCC 2022 Vol 2, H4D2

NCC 2022 Vol 2, H4D3

NCC 2022 Vol 1, F2D2

NCC 2022 Vol 2, H4D3

NCC 2022 HP, 10.2.15

AS 3740:2021, 4.8.2